[Effective in vivo radiation dose with image reconstruction controlled pedicle instrumentation vs. CT-based navigation].

Schaeren S, Roth J, Dick W

СтатьяПеревод в очереди

Аннотация

UNLABELLED: There is a rapid increase of computer-assisted surgery (CAS) in the spine for insertion of pedicle screws. In contrast to the traditional technique using fluoroscopy, CT is the primary source for surgical navigation systems.

PURPOSE OF THE STUDY: To compare organ and effective doses of fluoroscopy-controlled versus computer-assisted pedicle screw insertion under the aspect of risk reduction and number needed to treat.

MATERIALS AND

METHODS

In 20 consecutive cases of traditional pedicle screw instrumentation under fluoroscopic control the effective doses were recorded in vivo and the organ doses then calculated. Simulating a spiral CT necessary for the 3-D-model for navigation we defined a spiral CT protocol for the instrumented levels and calculated organ and effective doses from Monte Carlo Results from CT examinations.

RESULTS

Organ doses were clearly higher for the CT model than in any of the fluoroscopic procedures in vivo. The mean effective dose for the CT model was fifteen times higher than the fluoroscopic dose: 7.27 mSv versus 0.48 mSv.

CONCLUSIONS

In experienced hands open pedicle screw insertion in the thoracic and lumbar spine using fluoroscopy-control requires a fifteen times lower radiation dose than do CT scans necessary for computer-assisted surgery. Regarding the published small percentage of neurological complications in traditional screw insertion technique the use of computer-assisted surgery in pedicle screw insertion using CT scan should be limited to carefully chosen indications. The development of navigation systems based on other data sources than CT should be encouraged.

Для цитирования: Schaeren S, Roth J, Dick W. [Effective in vivo radiation dose with image reconstruction controlled pedicle instrumentation vs. CT-based navigation].. Der Orthopade. 2002. DOI: 10.1007/s00132-001-0281-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.