DOI 10.1177/230949900801600104
Balloon kyphoplasty for vertebra plana with or without osteonecrosis.
Аннотация
PURPOSE: To compare efficacy of balloon kyphoplasty in restoring vertebral height and correcting kyphosis in patients having vertebra plana with or without osteonecrosis.
METHODS
12 women and 3 men (mean age, 76 years), who had a complete vertebra plana with or without osteonecrosis (n=8 vs n=7), underwent balloon kyphoplasty. No external manoeuvres were performed before or during balloon kyphoplasty, except for positioning the patients in a prone posture on the operating table. The anterior, middle, and posterior vertebral height and the kyphotic angle were measured pre- and post-operatively with a digital imaging system. The vertebral height was measured as a percentage of the adjacent normal vertebral height.
RESULTS
Respectively in vertebra plana patients with or without osteonecrosis, the mean corrections of (1) kyphosis were 10 and 4 degrees (p=0.099), (2) anterior vertebral height were 33% and 5% (p<0.001), (3) middle vertebral height were 38% and 18% (p=0.004), and (4) posterior vertebral height were 19% and 2% (p=0.031).
CONCLUSION
In patients with vertebra plana, it is important to identify any osteonecrosis, which is an indication for balloon kyphoplasty to restore vertebral height and correct kyphosis.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.