MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00006123-199808000-00056

Медицинская библиотека · Neurosurgery · 1998

Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis.

Dickman C A, Sonntag V K

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To assess the outcomes associated with C1-C2 transarticular screw fixation.

METHODS

The clinical outcomes of 121 patients treated with posterior C1-C2 transarticular screws and wired posterior C1-C2 autologous bone struts were evaluated prospectively. Atlantoaxial instability was caused by rheumatoid arthritis in 48 patients, C1 or C2 fractures in 45, transverse ligament disruption in 11, os odontoideum in 9, tumors in 6, and infection in 2.

RESULTS

Altogether, 226 screws were placed under lateral fluoroscopic guidance. Bilateral C1-C2 screws were placed in 105 patients; each of 16 patients had only one screw placed because of an anomalous vertebral artery (n = 13) or other pathological abnormality. Postoperatively, each patient underwent radiography and computed tomography to assess the position of the screw and healing. Most screws (221 screws, 98%) were positioned satisfactorily. Five screws were malpositioned (2%), but none were associated with clinical sequelae. Four malpositioned screws were reoperated on (one was repositioned, and three were removed). No patients had neurological complications, strokes, or transient ischemic attacks. Long-term follow-up (mean, 22 mo) of 114 patients demonstrated a 98% fusion rate. Two nonunions (2%) required occipitocervical fixation. In comparison, our C1-C2 fixations with wires and autograft (n = 74) had an 86% union rate.

CONCLUSION

Rigidly fixating C1-C2 instability with transarticular screws was associated with a significantly higher fusion rate than that achieved using wired grafts alone. The risk of screw malpositioning and catastrophic vascular or neural injury is small and can be minimized by assessing the position of the foramen transversaria on preoperative computed tomographic scans and by using intraoperative fluoroscopy and frameless stereotaxy to guide the screw trajectory.

Для цитирования: Dickman C A, Sonntag V K. Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis.. Neurosurgery. 1998. DOI: 10.1097/00006123-199808000-00056.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.