Neonates With Tracheomalacia Generate Auto-Positive End-Expiratory Pressure via Glottis Closure.

Gunatilaka Chamindu C, Hysinger Erik B, Schuh Andreas, Gandhi Deep B, Higano Nara S, Xiao Qiwei, Hahn Andrew D, Fain Sean B, Fleck Robert J, Woods Jason C, Bates Alister J

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

In pediatrics, tracheomalacia is an airway condition that causes tracheal lumen collapse during breathing and may lead to the patient requiring respiratory support. Adult patients can narrow their glottis to self-generate positive end-expiratory pressure (PEEP) to raise the pressure in the trachea and prevent collapse. However, auto-PEEP has not been studied in newborns with tracheomalacia. The objective of this study was to measure the glottis cross-sectional area throughout the breathing cycle and to quantify total pressure difference through the glottis in patients with and without tracheomalacia.

RESEARCH QUESTION: Do neonates with tracheomalacia narrow their glottises? How does the glottis narrowing affect the total pressure along the airway?

STUDY DESIGN AND

METHODS

Ultrashort echo time MRI was performed in 21 neonatal ICU patients (11 with tracheomalacia, 10 without tracheomalacia). MRI scans were reconstructed at four different phases of breathing. All patients were breathing room air or using noninvasive respiratory support at the time of MRI. Computational fluid dynamics simulations were performed on patient-specific virtual airway models with airway anatomic features and motion derived via MRI to quantify the total pressure difference through the glottis and trachea.

RESULTS

The mean glottis cross-sectional area at peak expiration in the patients with tracheomalacia was less than half that in patients without tracheomalacia (4.0 ± 1.1 mm2 vs 10.3 ± 4.4 mm2; P = .002). The mean total pressure difference through the glottis at peak expiration was more than 10 times higher in patients with tracheomalacia compared with patients without tracheomalacia (2.88 ± 2.29 cm H2O vs 0.26 ± 0.16 cm H2O; P = .005).

INTERPRETATION: Neonates with tracheomalacia narrow their glottises, which raises pressure in the trachea during expiration, thereby acting as auto-PEEP.

Для цитирования: Gunatilaka Chamindu C, Hysinger Erik B, Schuh Andreas, Gandhi Deep B, Higano Nara S, Xiao Qiwei, Hahn Andrew D, Fain Sean B, Fleck Robert J, Woods Jason C, Bates Alister J. Neonates With Tracheomalacia Generate Auto-Positive End-Expiratory Pressure via Glottis Closure.. Chest. 2021. DOI: 10.1016/j.chest.2021.06.021.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.