INTRODUCTION

The outcomes of 106 total knee arthroplasties implanted using a soft tissue balancing surgical technique at one surgical centre were used to assess the accuracy maintaining the knee's original joint line (JL). The aim of the study was to determine whether there is a shift of the presumed joint line after surgery.

MATERIALS AND

METHODS

Preoperative and post-operative radiographs were compared to determine any changes in the articulation height. The preoperative distance of the fibular head to the natural joint line was measured and compared with the post-operative measurement of the fibular head to the femoral articulation line (measured on the radiograph and defined as Rxmm). Based on the actual medio-lateral dimension of the tibial metal back, the measured difference (RXmm) could be converted into true distances (in mm). The Blackburn-Peel index was assessed as an additional outcome prior to and following surgery.

RESULTS

Preoperatively, the average distance from the fibular head to the joint line was 15.1 Rxmm (SD 4.3) while the post-surgical distance was 15.5 Rxmm (SD 5.6). The average deviation of the post-surgical JL in relation to the original JL amounted to 0.4 Rxmm (SD 3.7). The average deviation of the joint line converted into the true distance was -0.3 mm (with a range of -5.9 mm in distal direction to + 8.3 mm in the proximal direction). Valgus position appeared to generate rather a shift in proximal direction whereas varus deformity favours a shift in distal direction. Seven patients exhibited a deviation of more than 5 mm in either the distal or proximal direction. All of the patients of this subgroup had a preoperative anatomical abnormality including a severe malalignment, serious bone destruction or had previously undergone a high tibial osteotomy.

CONCLUSION

An exact reconstruction of the natural Joint Line is achievable when using the described soft tissue balancing surgical technique with the posterior cruciate ligament (PCL) retaining prosthesis design used in this series.

Другие публикации по теме

Arthroplasty, Replacement, KneeKnee JointMathematicsRetrospective Studies
Для цитирования: Wyss T F, Schuster A J, Münger P, Pfluger D, Wehrli U. Does total knee joint replacement with the soft tissue balancing surgical technique maintain the natural joint line?. Archives of orthopaedic and trauma surgery. 2006. DOI: 10.1007/s00402-006-0171-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.