Jaganath Devan, Nabeta Pamela, Nicol Mark P, Castro Robert, Wambi Peter, Zar Heather J, Workman Lesley, Lodha Rakesh, Singh Urvashi B, Bavdekar Ashish, Sanghavi Sonali, Trollip André, Mace Aurélien, Bonnet Maryline, Lounnas Manon, de Haas Petra, Tiemersma Edine, Alland David, Banada Padmapriya, Cattamanchi Adithya, Ruhwald Morten, Wobudeya Eric, Denkinger Claudia M, Stool H2H Study Team

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

BACKGROUND

Centrifuge-free processing methods support stool Xpert Ultra testing for childhood tuberculosis, but data on their accuracy, acceptability, and usability are limited.

METHODS

We conducted a prospective evaluation of stool Xpert Ultra in India, South Africa, and Uganda with 3 methods: the Stool Processing Kit (SPK), the Simple One-Step method (SOS), and the Optimized Sucrose Flotation method (OSF). Children <15 years old with presumptive tuberculosis underwent sputum testing with Xpert Ultra and culture. We compared the accuracy of each method against a microbiological reference standard (tuberculosis if Xpert Ultra or culture positive) and a composite reference standard (tuberculosis if confirmed or unconfirmed tuberculosis). We surveyed laboratory staff to assess the acceptability and usability of the methods.

RESULTS

We included 607 children, with a median age of 3.5 years (interquartile range, 1.3-7 years); 15.5% were human immunodeficiency virus positive. Against the microbiological reference standard, the sensitivities of SPK, SOS, and OSF were 36.9% (95% confidence interval, 28.6%-45.8%), 38.6% (17.2%-51.0%), and 31.3% (20.2%-44.1%), respectively, and the specificities, 98.2% (96.4%-99.3%), 97.3% (93.7%-99.1%), and 97.1% (93.3%-99%). The methods were acceptable and usable, but SOS was reported as most feasible to implement in a peripheral facility. Across methods, sensitivities increased among children who were culture positive (range, 55.0%-77.3%) and were low (13%-16.7%) against the composite reference standard. Adding stool Xpert Ultra increased sensitivity from 0% (OSF) to 11.8% (SPK/SOS), compared with sputum alone.

CONCLUSIONS

Stool processing methods for Xpert Ultra were acceptable and usable and performed similarly, with highest sensitivity among children with culture-positive tuberculosis.

Для цитирования: Jaganath Devan, Nabeta Pamela, Nicol Mark P, Castro Robert, Wambi Peter, Zar Heather J, Workman Lesley, Lodha Rakesh, Singh Urvashi B, Bavdekar Ashish, Sanghavi Sonali, Trollip André, Mace Aurélien, Bonnet Maryline, Lounnas Manon, de Haas Petra, Tiemersma Edine, Alland David, Banada Padmapriya, Cattamanchi Adithya, Ruhwald Morten, Wobudeya Eric, Denkinger Claudia M, Stool H2H Study Team. Stool Processing Methods for Xpert Ultra Testing in Childhood Tuberculosis: A Prospective, Multicountry Accuracy Study.. Clinical infectious diseases : an official publication of the Infectious Diseases Society of America. 2026. DOI: 10.1093/cid/ciaf289.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.