Postoperative stability of bioresorbable plates made of 85:15 poly (L-lactide-co-glycolide) in Le Fort I osteotomy.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Tomomatsu Nobuyoshi, Takahara Namiaki, Akaike Yu, Sato Yudai, Kurasawa Yasuhiro, Yoda Tetsuya
Аннотация
OBJECTIVE: Recently, RapidSorb plates (DePuy Synthes) made of 85.15 poly (L-lactide-co-glycolide) have been used for orthognathic surgery; however, reports regarding their effectiveness are limited. We aimed to compare the postoperative stability of RapidSorb plates, RapidSorb combined with titanium (MOJ plates), and MOJ plates in patients who underwent Le Fort I osteotomy at Tokyo Medical and Dental University Hospital.
STUDY DESIGN: The use of RapidSorb in the maxilla is a load-sharing application and therefore constitutes an approved indication. Discrepancies in the maxillary positions were measured using postoperative computed tomography data at 1 week and 1 year using the centroid method 3-dimensionally. Treatment with RapidSorb alone showed a more vertical discrepancy in the maxilla treatment with MOJ and RapidSorb+MOJ. The RapidSorb4 group was subdivided into 2 groups (under and over 1.0-mm) based on the change in the maxillary centroid.
RESULTS: The bone gap at the lateral border of the piriform aperture was significantly larger in the over-1.0-mm group than in the 1.0-mm group.
CONCLUSIONS: The fixation of RapidSorb alone is not appropriate in load-bearing and unstable applications but is not contraindicated for load-sharing indications. Fixation with RapidSorb combined with MOJ was clinically effective, with results similar to titanium plate-only fixation regarding postoperative stability.
STUDY DESIGN: The use of RapidSorb in the maxilla is a load-sharing application and therefore constitutes an approved indication. Discrepancies in the maxillary positions were measured using postoperative computed tomography data at 1 week and 1 year using the centroid method 3-dimensionally. Treatment with RapidSorb alone showed a more vertical discrepancy in the maxilla treatment with MOJ and RapidSorb+MOJ. The RapidSorb4 group was subdivided into 2 groups (under and over 1.0-mm) based on the change in the maxillary centroid.
RESULTS: The bone gap at the lateral border of the piriform aperture was significantly larger in the over-1.0-mm group than in the 1.0-mm group.
CONCLUSIONS: The fixation of RapidSorb alone is not appropriate in load-bearing and unstable applications but is not contraindicated for load-sharing indications. Fixation with RapidSorb combined with MOJ was clinically effective, with results similar to titanium plate-only fixation regarding postoperative stability.