MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jor.1100070512

Медицинская библиотека · Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 1989

Quantitative histologic study of the influence of spinal instrumentation on lumbar fusions: a canine model.

Farey I D, McAfee P C, Gurr K R, Randolph M A

СтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

UNLABELLED: Histomorphometric and microradiographic studies were performed on 28 beagle hounds 1 year of age, followed up for 6 months after an L5-L6 anterior and posterior spinal destabilization procedure--Group I (n = 7), destabilized surgical controls; Group II (n = 7), posterolateral bone grafting after destabilization; Group III (n = 7), Harrington rod instrumentation and posterolateral bone grafting after destabilization; and Group IV (n = 7), Luque instrumentation, and bone grafting after destabilization. Six months postoperatively, device-related osteoporosis occurred in spines treated with spinal instrumentation. Within the L5 vertebral body the mean trabecular width was less for the two groups with instrumentation (Groups III and IV) compared with the two groups without instrumentation (Groups I and II) (p less than 0.001). The bone formation rate [mm3/(mm3 x year)] x 10(3), which is based on the mean distance between sequenced fluorochrome labels, for Group I (destabilized, nonfused, noninstrumented dogs) was more than twice that of the other three groups, which were all equivalent (p less than 0.05).

CLINICAL RELEVANCE: Stress shielding, or more correctly, device-related osteoporosis, probably can occur within vertebrae in response to rigid spinal instrumentation. However, the overall mechanical properties of vertebrae underlying spinal instrumentation are probably not at increased risk of fracture because the increase in cross-sectional area of the vertebra and incorporated fusion mass more than compensate for the loss of volumetric bone density.

Для цитирования: Farey I D, McAfee P C, Gurr K R, Randolph M A. Quantitative histologic study of the influence of spinal instrumentation on lumbar fusions: a canine model.. Journal of orthopaedic research : official publication of the Orthopaedic Research Society. 1989. DOI: 10.1002/jor.1100070512.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.