MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00256-024-04698-0

Медицинская библиотека · Skeletal radiology · 2024

Artificial intelligence improves resident detection of pediatric and young adult upper extremity fractures.

Zech John R, Ezuma Chimere O, Patel Shreya, Edwards Collin R, Posner Russell, Hannon Erin, Williams Faith, Lala Sonali V, Ahmad Zohaib Y, Moy Matthew P, Wong Tony T

СтатьяПеревод в очереди

Аннотация

PURPOSE: We wished to evaluate if an open-source artificial intelligence (AI) algorithm ( https://www.childfx.com ) could improve performance of (1) subspecialized musculoskeletal radiologists, (2) radiology residents, and (3) pediatric residents in detecting pediatric and young adult upper extremity fractures.

MATERIALS AND

METHODS

A set of evaluation radiographs drawn from throughout the upper extremity (elbow, hand/finger, humerus/shoulder/clavicle, wrist/forearm, and clavicle) from 240 unique patients at a single hospital was constructed (mean age 11.3 years, range 0-22 years, 37.9% female). Two fellowship-trained musculoskeletal radiologists, three radiology residents, and two pediatric residents were recruited as readers. Each reader interpreted each case initially without and then subsequently 3-4 weeks later with AI assistance and recorded if/where fracture was present.

RESULTS

Access to AI significantly improved area under the receiver operator curve (AUC) of radiology residents (0.768 [0.730-0.806] without AI to 0.876 [0.845-0.908] with AI, P < 0.001) and pediatric residents (0.706 [0.659-0.753] without AI to 0.844 [0.805-0.883] with AI, P < 0.001) in identifying fracture, respectively. There was no evidence of improvement for subspecialized musculoskeletal radiology attendings in identifying fracture (AUC 0.867 [0.832-0.902] to 0.890 [0.856-0.924], P = 0.093). There was no evidence of difference between overall resident AUC with AI and subspecialist AUC without AI (resident with AI 0.863, attending without AI AUC 0.867, P = 0.856). Overall physician radiograph interpretation time was significantly lower with AI (38.9 s with AI vs. 52.1 s without AI, P = 0.030).

CONCLUSION

An openly accessible AI model significantly improved radiology and pediatric resident accuracy in detecting pediatric upper extremity fractures.

Для цитирования: Zech John R, Ezuma Chimere O, Patel Shreya, Edwards Collin R, Posner Russell, Hannon Erin, Williams Faith, Lala Sonali V, Ahmad Zohaib Y, Moy Matthew P, Wong Tony T. Artificial intelligence improves resident detection of pediatric and young adult upper extremity fractures.. Skeletal radiology. 2024. DOI: 10.1007/s00256-024-04698-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.