MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0028-1109820

Медицинская библиотека · RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin · 2009

[Dual energy CT--a new perspective in the diagnosis of gout].

Artmann A, Ratzenböck M, Noszian I, Trieb K

СтатьяПеревод в очереди

Аннотация

PURPOSE: To describe the first experience with dual energy CT (DECT) for the diagnosis of gout and to evaluate its potential for the clinical routine.

MATERIALS AND

METHODS

DECT examinations acquired with a dual source CT of 71 regions from 41 patients were evaluated with respect to image quality, amount of urate deposits and their location. The amount of urate deposits was described using a 4-stage scale: none (1), minimal punctual (up to 2 mm) (2), at least moderate (bigger than 2 mm) (3), soft tissue or osseus tophi (4). The DECT results were compared with the findings of the diagnostic tools currently in use.

RESULTS

The DECTs of peripheral regions showed excellent image quality, while the image quality was poor in the regions of the trunk. Patients (n) and regions (r) with a score of 3 (n = 23, r = 44), 4 (n = 5, r = 8) and 1 (n = 2, r = 2) showed a highly significant correlation (p < 0.01) with the currently available diagnostic tools. In patients or regions with a score of 2 (n = 7, r = 11), the urate deposits were asymptomatic, the serum urate levels were partly elevated (43 %) and partly normal (57 %). The symptoms were ultimately able to be associated with a differential diagnosis. The urate deposits were found in tendons (57), articular synovia (25), cartilage (17), soft tissue tophi (8), osseus tophi (5), cruciate ligaments (7) and menisci (7).

CONCLUSION

DECT allows specific and quantitative visualization of urate deposits in peripheral regions. Taking into account the amount of urate deposits shown in DECT, the diagnosis of gout can be stated reliably. Based on our experience and results, DECT greatly benefits the routine diagnosis of gout in peripheral regions.

Для цитирования: Artmann A, Ratzenböck M, Noszian I, Trieb K. [Dual energy CT--a new perspective in the diagnosis of gout].. RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. 2009. DOI: 10.1055/s-0028-1109820.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.