MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/vsu.13399

Медицинская библиотека · Veterinary surgery : VS · 2020

Ex vivo mechanical properties of a 2.5-mm bone anchor for treatment of cranial cruciate ligament rupture in toy breed dogs.

Roca Rodrigo Y, Peura Aliisa, Kowaleski Michael P, Watson Mallory T, Lendhey Matin, Rocheleau P J, Hulse Donald A

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To determine the mechanical pull-out properties of a 2.5-mm bone anchor implanted in ex vivo femurs of toy breed dogs and to determine whether there is a difference between knotted and knotless configurations.

STUDY

DESIGN

Experimental study.

SAMPLE POPULATION: Eight paired harvested femurs.

METHODS

Femurs were assigned to knotted or knotless configuration. Equal numbers of right and left femurs were tested. The caudolateral femoral condyle at the distal pole of the lateral fabella (F2 site) was drilled. The assigned configuration with braided suture combined with the bone anchor was implanted into the F2 site. Each configuration was positioned into a mechanical testing machine to measure yield load, load at 3-mm displacement, ultimate load, stiffness, and mode of failure at the beginning of the canine standing phase angle (150°).

RESULTS

Mean ultimate load was 100.14 and 88.69 N (P = .798), mean yield load was 59.72 and 55.85 N (P = .708), load at 3-mm displacement was 46.72 and 43.33 N (P = .656), and stiffness was calculated to be 43.06 and 47.09 N/mm (P = .548) for knotted and knotless configurations, respectively. Mode of failure occurred primarily by anchor pull-out.

CONCLUSION

The bone anchor withstood deformation at the estimated forces applied on the native cranial cruciate ligament (CCL) of toy breed dogs in both configurations.

CLINICAL SIGNIFICANCE: This bone anchor may constitute a useful alternative for stabilization of the CCL deficient stifle in toy breed dogs. However, before it can be recommended for widespread use in dogs, closely monitored clinical trials must be conducted to assess outcome and complications associated with this implant.

Для цитирования: Roca Rodrigo Y, Peura Aliisa, Kowaleski Michael P, Watson Mallory T, Lendhey Matin, Rocheleau P J, Hulse Donald A. Ex vivo mechanical properties of a 2.5-mm bone anchor for treatment of cranial cruciate ligament rupture in toy breed dogs.. Veterinary surgery : VS. 2020. DOI: 10.1111/vsu.13399.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.