Novel implant-free loop Tenodesis vs. simple Tenotomy of the long biceps tendon - a biomechanical investigation.
Аннотация
BACKGROUND
Simple tenotomy and anchor tenodesis are commonly used in treatment of long biceps tendon (LHB) pathologies. The tenotomy can result in biceps distalization or cosmetic deformities. A novel loop Tenodesis Technique (LTD) could prevent a distalization of the biceps muscle without the risk of implant associated complications. The purpose of this study was to investigate the biomechanical aspects of the novel LTD compared to a standard tenotomy of the LHB. It has been hypothesized that the novel technique will show biomechanical superiority in terms of resistance and distalization.
METHODS
Seven paired adult human cadaveric shoulder joints were assigned to one of the two study groups: Loop tenodesis (LTD); simple tenotomy (STT). In both groups load-to-failure testing was performed. The load-displacement curve was used to determine the maximum load (N), the degree of distalization of the LHB (mm) and the stiffness (N/mm). Additionally, the mode of failure was registered.
RESULTS
The LTD group achieved a significantly higher ultimate load to failure (LTD: 50.5 ± 12.5 N vs. STT: 6.6 ± 3.9 N; p = 0.001). Significantly less distalization of the tendon could be detected for the LTD group (LTD: 8 ± 2.3 mm vs. STT: 22.4 ± 2.4 mm; p = 0.001). Stiffness was 7.4 ± 3.9 N/mm for the LTD group and 0.23 ± 0.16 N/mm for the STT group (p = 0.001). In all specimens of the LTD group a tendon rupture was found as mode of failure, while the STT group failed because of pulling out the LHB through the bicipital groove.
CONCLUSION
The novel loop Tenodesis Technique shows biomechanically higher stability as well as less distalization compared to a simple tenotomy of the long biceps tendon.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.