MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/jars.2002.29938

Медицинская библиотека · Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association · 2002

Juxta-articular bone marrow signal changes on magnetic resonance imaging following arthroscopic meniscectomy.

Kobayashi Yasukazu, Kimura Masashi, Higuchi Hiroshi, Terauchi Masanori, Shirakura Kenji, Takagishi Kenji

СтатьяПеревод в очереди

Аннотация

PURPOSE: Postmeniscectomy osteonecrosis of the knee has been reported in the past decade but the etiology remains unclear. Some investigators have indicated that bone marrow signal changes evident on magnetic resonance imaging (MRI) could be early warning signs of osteonecrosis. The purpose of this study was to determine the incidence rate, location, and magnitude of such changes in bone marrow of the knee after arthroscopic meniscectomy, using MRI.

TYPE OF STUDY: Cohort analytic study.

METHODS

Ninety-three patients with no bone marrow signal abnormalities on preoperative MRI were examined after isolated arthroscopic meniscectomy. There were 51 men and 42 women with an age range of 11 to 62 years (mean, 36.6 years). Of the total, 57 patients underwent partial meniscectomy (34 medial and 23 lateral) and the others total meniscectomy (10 medial and 26 lateral). MRI examinations were performed independently of postoperative knee symptoms, 1 to 24 months after surgery. Bone marrow changes of the treated knees were evaluated by T1- and T2*-weighted MRI.

RESULTS

Thirty-two of 93 patients (34%) had bone marrow signal changes in femoral or tibial condyles shown on postoperative MRI. No patients had these changes in the femoral or tibial condyles opposite from the meniscectomy side and, in the majority of cases, the size was less than half that of the condyle. Fifteen of the 44 patients who underwent medial meniscectomy and 17 of the 49 patients who underwent lateral meniscectomy had such changes. The meniscectomy side did not affect the incidence rate, and frequently both femoral and tibial condyles were involved. Age, gender and articular cartilage condition at the surgery were not risk factors. In contrast, the extent of meniscectomy affected the incidence rate.

CONCLUSIONS

This study suggests a positive correlation between arthroscopic meniscectomy and postoperative bone marrow signal changes of the knee.

Для цитирования: Kobayashi Yasukazu, Kimura Masashi, Higuchi Hiroshi, Terauchi Masanori, Shirakura Kenji, Takagishi Kenji. Juxta-articular bone marrow signal changes on magnetic resonance imaging following arthroscopic meniscectomy.. Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association. 2002. DOI: 10.1053/jars.2002.29938.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.