Circumferential dynamic stabilization of the lumbar spine: a biomechanical analysis.

Käfer Wolfram, Cakir Balkan, Midderhoff Stefan, Reichel Heiko, Wilke Hans-Joachim

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: To assess segmental angulation and mobility following implantation of the Charité artificial disc in combination with the posterior dynamic fixation device dynamic stabilization system (DSS) and the interspinous spacer Coflex at the L4-L5 segment, respectively.

METHODS

Six human L4-L5 specimens were loaded with pure moments of ±7.5 Nm in flexion/extension, lateral bending, and axial rotation in a custom-made spine tester. The testing protocol was as follows: (a) intact condition, (b) destabilization by resection of the anterior longitudinal ligament (ALL), (c) implantation of the Charité with retained posterior longitudinal ligament (PLL), (d) supplemental DSS implantation, (e) removal of DSS rods and PLL resection, (f) DSS rod re-implantation, (g) enlargement of rod length, and (h) removal of DSS and implantation of Coflex. Range of motion (ROM), neutral zone, and segmental angulation were determined.

RESULTS

ALL resection did not influence significantly ROM. TDR increased lateral bending and axial rotation only after resection of the PLL, whereas flexion/extension remained unchanged. DSS limited all degrees of freedom prior to and after PLL resection. Rod length enlargement had no significant effect. Coflex limited significantly flexion/extension compared to the intact state and TDR, whereas lateral bending and axial rotation remained unchanged. TDR increased lordosis, whereas Coflex had a substantial kyphosing effect.

CONCLUSIONS

This study demonstrates that posterior dynamic stabilization in combination with TDR reduces flexion/extension ROM and segmental lordosis in a monosegmental biomechanical model.

Для цитирования: Käfer Wolfram, Cakir Balkan, Midderhoff Stefan, Reichel Heiko, Wilke Hans-Joachim. Circumferential dynamic stabilization of the lumbar spine: a biomechanical analysis.. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2014. DOI: 10.1007/s00586-014-3286-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.