The influence of cardiac arrhythmias on the detection of heartbeats in the photoplethysmogram: benchmarking open-source algorithms.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Jeanningros Loïc, Le Bloa Mathieu, Teres Cheryl, Herrera Siklody Claudia, Porretta Alessandra Pia, Pascale Patrizio, Luca Adrian, Solana Muñoz Jorge, Domenichini Giulia, Meister Théo A, Soria Maldonado Rodrigo, Tanner Hildegard, Vesin Jean-Marc, Thiran Jean-Philippe, Lemay Mathieu, Rexhaj Emrush, Pruvot Etienne, Braun Fabian
Аннотация
Objective.Cardiac arrhythmias are a leading cause of mortality worldwide. Wearable devices based on photoplethysmography give the opportunity to screen large populations, hence allowing for an earlier detection of pathological rhythms that might reduce the risks of complications and medical costs. While most of beat detection algorithms have been evaluated on normal sinus rhythm or atrial fibrillation recordings, the performance of these algorithms in patients with other cardiac arrhythmias, such as ventricular tachycardia or bigeminy, remain unknown to date.Approach. ThePPG-beatsopen-source framework, developed by Charlton and colleagues, evaluates the performance of the beat detectors namedQPPG,MSPTDandABDamong others. We applied thePPG-beatsframework on two newly acquired datasets, one containing seven different types of cardiac arrhythmia in hospital settings, and another dataset including two cardiac arrhythmias in ambulatory settings.Main Results. In a clinical setting, theQPPGbeat detector performed best on atrial fibrillation (with a medianF1score of 94.4%), atrial flutter (95.2%), atrial tachycardia (87.0%), sinus rhythm (97.7%), ventricular tachycardia (83.9%) and was ranked 2nd for bigeminy (75.7%) behindABDdetector (76.1%). In an ambulatory setting, theMSPTDbeat detector performed best on normal sinus rhythm (94.6%), and theQPPGdetector on atrial fibrillation (91.6%) and bigeminy (80.0%).Significance. Overall, the PPG beat detectorsQPPG,MSPTDandABDconsistently achieved higher performances than other detectors. However, the detection of beats from wrist-PPG signals is compromised in presence of bigeminy or ventricular tachycardia.