STUDY

OBJECTIVE

Erector spinae plane (ESP) blocks have been recently described for postoperative pain management following spine surgery but their effects on intraoperative neuromonitoring are unknown.

DESIGN

Retrospective cohort study.

SETTING

Pediatric patients at a tertiary care center.

PATIENTS: 26 pediatric patients who received bilateral surgically-placed ESP catheters for single-stage posterior spine fusion (PSF) from August 2020 to June 2021.

INTERVENTIONS: Patients in this study did not receive any special interventions as part of this observational retrospective study.

MEASUREMENTS: This retrospective study investigated the effects of local anesthesia administration through bilateral surgically-placed ESP catheters on intraoperative intercostal transcranial motor evoked potentials (tcMEPs) in the setting of a disrupted erector spinae fascial plane in pediatric patients undergoing single-stage posterior spine fusion.

MAIN

RESULTS

Of the 26 patients that received bilateral surgically-placed ESP catheters for pediatric posterior spine fusion surgery, none exhibited any changes in intercostal tcMEPs attributable to intraoperative lidocaine administration through the ESP catheters.

CONCLUSIONS

The administration of a local anesthetic into a disrupted erector spinae fascial plane does not appear to interfere with intraoperative neuromonitoring of posterior spine fusion surgeries.

Для цитирования: Pan Stephanie J, Vorhies John S, Lee Leslie H, López Jaime R, Tsui Ban C H. The effect of intraoperative lidocaine administration in a disrupted erector spinae fascial plane on intercostal transcranial motor evoked potentials.. Journal of clinical anesthesia. 2022. DOI: 10.1016/j.jclinane.2022.110956.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.