MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/md.0000000000021696

Медицинская библиотека · Medicine · 2020

Is biodegradable pin a good choice for lateral condylar fracture of humerus in children: A comparative study of biodegradable pin and Kirschner wire.

Li Jin, Rai Saroj, Liu Yudong, Ze Renhao, Tang Xin, Liu Ruikang, Hong Pan

Сравнительное исследованиеСтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

INTRODUCTION

Lateral condylar fracture (LCF) of the humerus in children is one of the commonest elbow injuries in children. Early recognition of the problem and appropriate management usually yields satisfactory outcomes. Closed or open reduction with Kirschner-wire (KW) is a cost-effective choice of fixation method for displaced fracture. However, various other methods, including partially threaded cannulated cancellous screw and biodegradable pin (BP), have also been used. This study aimed to investigate the efficacy of BP and compare its clinical outcomes with KW.

MATERIAL AND

METHODS

Patients with LCF admitted from January 2008 to January 2016 at our institute were reviewed retrospectively. Baseline information and clinical data were collected from Hospital Database. Patients were divided into the KW group and BP group.

RESULTS

In all, 85 patients (male 50, female 35) in the KW group and 76 patients (male 47, female 29) in the BP group were included in this study. The average age of patients in the KW group was 5.2 years, and that of BP was 5.9 years. No nonunion or malunion was observed in either group. At the last follow-up visit, there was no statistically significant difference between the 2 groups with regard to elbow function and appearance. The incidence of long-term complications, including avascular necrosis, fishtail deformity, and lateral prominence, showed no significant difference between both the groups. The incidence of hardware prominence was higher in the KW (13/85, 15.6%) than BP (2/76, 2.6%) group (P < .001).

CONCLUSIONS

Both KW and BP are safe and effective choices for LCF of the humerus in children. Both the implant designs produce satisfactory and comparable clinical outcomes. However, BP has the advantage of less hardware prominence, no need for hardware removal, and fewer long-term complications.

Для цитирования: Li Jin, Rai Saroj, Liu Yudong, Ze Renhao, Tang Xin, Liu Ruikang, Hong Pan. Is biodegradable pin a good choice for lateral condylar fracture of humerus in children: A comparative study of biodegradable pin and Kirschner wire.. Medicine. 2020. DOI: 10.1097/md.0000000000021696.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.