MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/1076029608319879

Медицинская библиотека · Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/Hemostasis · 2008

The effectiveness of measuring for fragmented red cells using an automated hematology analyzer in patients with thrombotic microangiopathy.

Abe Yasunori, Wada Hideo, Yamada Eri, Noda Maki, Ikejiri Makoto, Nishioka Junji, Kobayashi Toshihiko, Matsumoto Takeshi, Masuya Masahiro, Isaji Syuji, Usui Masanobu, Uemoto Sinji, Katayama Naoyuki, Nobori Tsutomu

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Thrombotic microangiopathy (TMA) or thrombotic thrombocytopenic purpura (TTP) is a life-threatening syndrome characterized by increased number of fragmented red cells (FRCs) and thrombocytopenia. FRCs can be measured using the recently developed automated hematology analyzer XE-2100. The normal range for FRCs is 0% to 0.205%, as determined by the automated hematology analyzer XE-2100. The FRC count is significantly elevated in patients with TMA associated with liver transplantation, bone marrow transplantation, or TTP. In patients with TMA after liver transplantation, the FRC count is significantly higher than in those without TMA. In receiver operating characteristic analysis for the diagnosis of TMA, the area under the curve is 0.986, suggesting that FRC is a useful marker for the diagnosis of TMA. When the cutoff value of FRC for TMA is 1.2%, the sensitivity is 90% and the specificity is 96%, indicating that FRC is the most useful screening test for the diagnosis of TMA.

Для цитирования: Abe Yasunori, Wada Hideo, Yamada Eri, Noda Maki, Ikejiri Makoto, Nishioka Junji, Kobayashi Toshihiko, Matsumoto Takeshi, Masuya Masahiro, Isaji Syuji, Usui Masanobu, Uemoto Sinji, Katayama Naoyuki, Nobori Tsutomu. The effectiveness of measuring for fragmented red cells using an automated hematology analyzer in patients with thrombotic microangiopathy.. Clinical and applied thrombosis/hemostasis : official journal of the International Academy of Clinical and Applied Thrombosis/Hemostasis. 2008. DOI: 10.1177/1076029608319879.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.