PURPOSE: The ergonomic problems for surgeons during spine surgery are an awkward body posture, repetitive movements, increased muscle activity, an overflexed spine, and a protracted time in a standing posture. The authors analyzed whole spine angles during discectomy. The objective of this study is to assess differences in surgeon whole spines angles according to operating table height and the methods used to visualize surgical field.

MATERIALS AND

METHODS

A cohort of 12 experienced spine surgeons was enrolled. Twelve experienced spine surgeons performed discectomy using a spine surgery simulator. Three different methods were used to visualize the surgical field (naked eye, loupe, and out of loupe) and three different operating table heights. Whole spine angles were compared for three different views during discectomy simulation; midline, ipsilateral, and contralateral. A 16-camera optoelectronic motion analysis system was used, and 16 markers were placed from head to pelvis. Lumbar lordosis, thoracic kyphosis, cervical lordosis, and occipital angle were compared at the different operating table heights, while using the three visualization methods, with natural standing position.

RESULTS

Whole spine angles were significantly different for visualization methods. Lumbar lordosis, cervical lordosis, and occipital angle were closer to natural standing values when discectomy was performed with a loupe, but most measures differed from natural standing values when performed out of loupe. Thoracic kyphosis was also similar to the natural standing position during discectomy using a loupe, but differed from the natural standing position when performed with naked eye. Whole spine angles were also found to differ from the natural standing position according to operating table height, and became closer to natural standing position values as operating table height increased, when simulation was conducted with loupe.

CONCLUSION

This study suggests that loupe use and a table height midpoint between the umbilicus and sternum are optimal for reducing surgeon musculoskeletal fatigue.

Для цитирования: Park Jeong Yoon, Kim Kyung Hyun, Kuh Sung Uk, Chin Dong Kyu, Kim Keun Su, Cho Yong Eun. Spine surgeon's kinematics during discectomy according to operating table height and the methods to visualize the surgical field.. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2012. DOI: 10.1007/s00586-012-2425-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.