Kyung Min Gyu, Bae Tae Soo, Baek Hyeong Ho, Chang Moon Jong, Kim Tae Woo, Kang Seung-Baik
Аннотация
BACKGROUND: While the concept of a safe zone, which can minimize the hinge fracture when performing opening wedge high tibial osteotomy, has been introduced, there is a lack of understanding of the biomechanical environment at the lateral tibial cortex. This study aimed to evaluate the effect of the hinge level on the biomechanical environment at the lateral cortex of the tibia with heterogeneous finite element models.
METHODS: Finite element models of biplanar opening wedge high tibial osteotomy based on computed tomography images of a control subject and three patients with medial compartment knee osteoarthritis were created. In each model, three different hinge levels (proximal, middle, and distal) were set. The process of opening the gap during the operation was simulated, and the maximum von Mises stress values at the lateral tibial cortex were calculated for each hinge level and correction angle.
FINDINGS: The maximum von Mises stress value at the lateral tibial cortex was the lowest when the hinge was at the middle, while the value was the highest when the hinge was at the distal level. Furthermore, it was demonstrated that a higher correction angle yielded a higher probability of lateral tibial cortex fracture.
INTERPRETATION: The findings of this study demonstrate that the hinge at the point where the upper end of the articular cartilage of the proximal tibiofibular joint is located provides the least possibility of lateral tibial cortex fracture, as this is an anatomically independent position from the fibula.
METHODS: Finite element models of biplanar opening wedge high tibial osteotomy based on computed tomography images of a control subject and three patients with medial compartment knee osteoarthritis were created. In each model, three different hinge levels (proximal, middle, and distal) were set. The process of opening the gap during the operation was simulated, and the maximum von Mises stress values at the lateral tibial cortex were calculated for each hinge level and correction angle.
FINDINGS: The maximum von Mises stress value at the lateral tibial cortex was the lowest when the hinge was at the middle, while the value was the highest when the hinge was at the distal level. Furthermore, it was demonstrated that a higher correction angle yielded a higher probability of lateral tibial cortex fracture.
INTERPRETATION: The findings of this study demonstrate that the hinge at the point where the upper end of the articular cartilage of the proximal tibiofibular joint is located provides the least possibility of lateral tibial cortex fracture, as this is an anatomically independent position from the fibula.