Fracture Resistance of CAD/CAM Monolithic Zirconia Crowns Supported by Titanium and Ti-Base Abutments: The Effect of Chewing Simulation and Thermocyclic Aging.

Yavuz Ayşe, Büyükerkmen Emine Begüm

СтатьяПеревод в очереди

Аннотация

Purpose: To evaluate the effect of chewing simulation and thermocyclic aging on the fracture resistance of CAD/CAM monolithic zirconia crowns supported by titanium and Ti-base abutments. Materials and

Methods

Two implant abutment groups-titanium (Ti) and titanium base (Ti-base; Medentika)-were used. A total of 40 mandibular first molar CAD/CAM monolithic zirconia crowns (Vita YZ T) were fabricated, then cemented onto the abutments with Panavia V5. Each abutment group was divided into two subgroups (n = 10). The Ti and Ti-base groups were subjected to a single load until fracture, and the Ti/CT and Ti-base/CT groups (CT: chewing simulation and thermocyclic aging) underwent chewing simulation (1.2 × 106 cycles × 50 N load, 1.4 Hz) and thermocylic aging (3,911 cycles/5°C to 55°C). The fracture resistances of the crowns were tested with a universal testing machine (1 mm/minute). Shapiro-Wilk and one-way ANOVA test were used for statistical analysis (P = .05).

Results

The survival rates after chewing simulation and thermocyclic aging were 100% for both CT groups. The fracture resistance values (mean ± SD) of the groups were as follows: Ti = 1,718.18 ± 331.06 N, Ti-base = 1,713.53 ± 233.24 N, Ti/CT = 1,664.82 ± 188.62 N, and Ti-base/CT = 1,551.28 ± 344.79 N. According to one-way ANOVA test results, there was no statistically significant difference between the four groups (P = .526).

Conclusion

CAD/CAM monolithic zirconia crowns supported by Ti-base or titanium abutments were found to have sufficient fracture resistance in the treatment of an absent single posterior tooth. However, more in vitro and clinical studies are required to evaluate the long-term performance of Ti-base abutments and CAD/CAM zirconia crowns.

Для цитирования: Yavuz Ayşe, Büyükerkmen Emine Begüm. Fracture Resistance of CAD/CAM Monolithic Zirconia Crowns Supported by Titanium and Ti-Base Abutments: The Effect of Chewing Simulation and Thermocyclic Aging.. The International journal of oral & maxillofacial implants. 2023. DOI: 10.11607/jomi.9693.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.