MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arthro.2019.08.043

Медицинская библиотека · Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association · 2019

Preoperative Validation of the Patient-Reported Outcomes Measurement Information System in Patients With Articular Cartilage Defects of the Knee.

Shamrock Alan G, Wolf Brian R, Ortiz Shannon F, Duchman Kyle R, Bollier Matthew J, Carender Christopher N, Westermann Robert W

Сравнительное исследованиеСтатьяВалидационное исследованиеПеревод в очереди

Аннотация

PURPOSE: To validate the Patient-Reported Outcomes Measurement Information System (PROMIS) physical function computer adaptive test (PF CAT) with current patient-reported outcome (PRO) instruments in patients with cartilage injuries of the knee.

METHODS

Patients scheduled for osteochondral autograft or allograft transplant, microfracture, autologous chondrocyte implantation, allograft cartilage resurfacing, and chondroplasty were prospectively enrolled in the study and completed PROMIS PF CAT, Knee Injury and Osteoarthritis Outcome Score (KOOS activities of daily living, pain, symptoms, sport, and quality of life), Short Form-36 Health Survey (SF-36 physical function [PF] and Physical Component Summary), and EuroQol-5 Dimension questionnaires. The Spearman correlation coefficient was used to compare instruments. Instrument correlations were defined as excellent (>0.7), excellent to good (0.61-0.69), good (0.4 to 0.6), and poor (<0.39), with significance defined as P < .05.

RESULTS

A total of 293 knees in 275 patients (54.5% male) undergoing 319 cartilage procedures were analyzed. The most commonly performed cartilage procedure was chondroplasty (n = 118; 37.0%), followed by microfracture (n = 100; 31.3%). The mean age was 34.0 ± 14.7 and the mean body mass index was 30.0 ± 6.9. The PROMIS PF CAT had an excellent correlation with the SF-36 PF (r = 0.819; P < .001), SF-36 Physical Component Summary (r = 0.766; P < .001), KOOS activities of daily living (r = 0.733; P < .001), KOOS Sport (r = 0.709; P < .001), and EuroQol-5 Dimension (r = 0.752; P < .001) instruments; an excellent-good correlation with the KOOS pain (r = 0.662; P < .001), and KOOS quality of life (r = 0.640; P < .001) scores; and a good correlation with the KOOS symptoms (r = 0.519; P < .001) scale. The PROMIS PF CAT had no floor or ceiling effects and the smallest question burden (mean 4.17 ± 0.93 questions). Dimensionality analyses demonstrated that the smallest amount of unexplained variance was present in the PROMIS PF CAT (3.6%).

CONCLUSION

The PROMIS PF CAT is an effective tool for preoperative outcome assessment in patients with cartilage defects of the knee. It correlates strongly with legacy PRO measures of physical function with no ceiling and floor effects and a minimal time burden for completion. Further study is warranted to determine postoperative performance and to evaluate the responsiveness of PROMIS to change within a patient.

LEVEL OF EVIDENCE: III; Prognostic retrospective comparative study.

Для цитирования: Shamrock Alan G, Wolf Brian R, Ortiz Shannon F, Duchman Kyle R, Bollier Matthew J, Carender Christopher N, Westermann Robert W. Preoperative Validation of the Patient-Reported Outcomes Measurement Information System in Patients With Articular Cartilage Defects of the Knee.. Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association. 2019. DOI: 10.1016/j.arthro.2019.08.043.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.