Intraoperative stitched fluoroscopic images: effect of parallax on angular measurements of the spine.

Ellingson Arin M, Boelter Kaitlyn, Sembrano Jonathan N, Takahashi Takashi, Polly David W

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND CONTEXT: Intraoperative stitched O-arm images are commonplace during spinal deformity correction surgeries; however, the accuracy of stitched images for measuring angular measures is unknown.

PURPOSE: To examine the effect of radiographic parallax effect of stitched O-arm images by assessing the regional curve agreement with measurements from computed tomography (CT).

STUDY DESIGN/

SETTING

Experimental radiographic study.

PATIENT SAMPLE: Four whole body cadavers (age: 81±14, sex: 2M/2F) and two fabricated spine model phantoms from surgical cases, one with extreme scoliosis and one normal spine, were utilized.

OUTCOME MEASURES: The limits of agreement for angular measures between CT (gold-standard) and intraoperative stitched fluoroscopic images were calculated. Further, intra- and inter-rater reliability was measured.

METHODS

A series of adjacent anterior-posterior and lateral images were acquired cranial to caudal using an O-arm in three table configurations (standard position, off-axis in the coronal plane, and reverse Trendelenburg) and stitched manually. Regional angular measures were extracted, and the limits of agreement were calculated between each table position and CT using a Bland-Altman approach.

RESULTS

The observers displayed excellent inter-rater reliability across table positions (range: 0.944-0.989) and intra-rater reliability (0.979-0.995). The limits of agreement results showed a similar and better agreement was observed for the Standard and Reverse Trendelenburg than the Off-Axis position.

CONCLUSIONS

This work shows reliable regional curvature measurements can be calculated with good agreement with CT in common table positions, but care should be taken to ensure the patient is perpendicular to the X-rays, particularly in the lateral view.

Для цитирования: Ellingson Arin M, Boelter Kaitlyn, Sembrano Jonathan N, Takahashi Takashi, Polly David W. Intraoperative stitched fluoroscopic images: effect of parallax on angular measurements of the spine.. The spine journal : official journal of the North American Spine Society. 2022. DOI: 10.1016/j.spinee.2022.01.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.