MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/brs.0000000000004226

Медицинская библиотека · Spine · 2021

Intraoperative Cone Beam CT in Hybrid Operation Room for Pediatric Scoliosis Patients: Comparison of Pedicle Screw Violation Rate at Normal and Low Radiation Doses.

Tanikawa Yusuke, Oba Hiroki, Fujii Masahiro, Ikegami Shota, Uehara Masashi, Mimura Tetsuhiko, Miyagawa Jun, Hatakenaka Terue, Kuraishi Shugo, Takizawa Takashi, Munakata Ryo, Kamanaka Takayuki, Miyaoka Yoshinari, Michihiko Koseki, Takahashi Jun

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

STUDY

DESIGN

Retrospective observational study.

OBJECTIVE

This study aimed to determine the effect of reducing the radiation dose of intraoperative cone beam computed tomography (CBCT) during posterior spinal fusion (PSF) for pediatric scoliosis on the rate of pedicle screw (PS) violation.

SUMMARY OF BACKGROUND DATA: Intraoperative CBCT for pediatric scoliosis improves the accuracy of PS insertion in PSF. However, few reports have addressed the PS perforation rate from reduced radiation doses in hybrid navigation.

METHODS

We evaluated 855 PSs inserted into 58 pediatric scoliosis patients (11 male and 47 female, mean age: 16.6 yr) who underwent PSF using CBCT. A radiation dose of 1/3 or 1/5 of the normal dose (ND) was defined as a low dose (LD). After PS insertion, intraoperative CBCT images were reviewed to assess the degree of PS perforation. G2-3 (i.e., perforations of 4 mm or more) was defined as a violation. The PS violation rate was compared between the groups, and factors associated with violations were examined.

RESULTS

A total of 567 and 288 screws were inserted in the ND group and LD group, respectively. The PS violation rate was comparable at 1.8% in the ND group and 1.7% in the LD group. Multiple logistic regression analysis showed that distance from the upper instrumented vertebra (UIV) was an independently associated factor of PS violation (+1 vertebra, operation room 0.73, P   =  0.038). In addition, the mean height of patients with PS violations (148.8 ± 3.6 cm) was significantly shorter than that of patients without violations (157.9 ± 1.2 cm) ( P  = 0.034).

CONCLUSION

There was no increase in PS violation rate with lower doses of radiation for intraoperative navigation CBCT. Extra care is warranted for vertebrae close to the UIV and patients of shorter stature.Level of Evidence: 3.

Для цитирования: Tanikawa Yusuke, Oba Hiroki, Fujii Masahiro, Ikegami Shota, Uehara Masashi, Mimura Tetsuhiko, Miyagawa Jun, Hatakenaka Terue, Kuraishi Shugo, Takizawa Takashi, Munakata Ryo, Kamanaka Takayuki, Miyaoka Yoshinari, Michihiko Koseki, Takahashi Jun. Intraoperative Cone Beam CT in Hybrid Operation Room for Pediatric Scoliosis Patients: Comparison of Pedicle Screw Violation Rate at Normal and Low Radiation Doses.. Spine. 2021. DOI: 10.1097/brs.0000000000004226.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.