MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12891-022-05897-3

Медицинская библиотека · BMC musculoskeletal disorders · 2022

Finite element analyses of lateral condyle fracture fixation in paediatrics regarding configuration of Kirschner-wire.

Jeon Sangbin, Ahn Wooyeol, Oh Jongbeom, Chung Jaiwoo, Choi Junwon, Lee Soonchul

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

This study aimed to discover the most stable outcome among different Kirschner-wire (K-wire) configurations for fixation of a lateral condyle fracture (Milch type II) in different loads of stress by using finite element analyses (FEA).

METHODS

The right humerus of a 6-year-old boy with a lateral condyle fracture (Milch type II), was modelled with a computer aided engineering. Using FEA, peak von Mises stress and stiffness were evaluated first for a single K-wire fixation by varying the angle (0, 5, 10, 15, 20, 25, 30 degrees). Then, based on the single K-wire result, assessment of peak von Mises stress and stiffness were evaluated via FEA for two- or three-wire fixation under various configurations (two convergent, two parallel, three divergent).

RESULTS

Single K-wire fixation by 5 and 25 degrees had the lowest peak von Mises stress. The fracture site showed higher stiffness at 0, 5 and 15 degrees. Considering the collected results and clinical situation, 5 degree K-wire was selected for the FEA of multiple K-wire fixation. For multiple K-wire fixation, three divergent (5-20-35 degrees) K-wires showed better stability, both in peak von Mises stress and stiffness, than any two-K-wire configurations. Among two K-wire fixations, two divergent (5-50 degrees) K-wires provided the lowest von Mises stress in varus and valgus while two divergent (5-65 degrees) K-wires showed better results in flexion, extension, internal and external rotation, and both configurations showed similar results in stiffness.

CONCLUSIONS

We successfully created a paediatric lateral condyle fracture (Milch type II) model which was used to conduct FEA on different K-wire configurations to achieve stability of the fracture. Our results show that an initial K-wire inserted at 5 degrees, followed by the insertion of a second divergent wire at either 45 or 60 degrees provides the most stability in two K-wire fixations in this type of fracture repair.

Для цитирования: Jeon Sangbin, Ahn Wooyeol, Oh Jongbeom, Chung Jaiwoo, Choi Junwon, Lee Soonchul. Finite element analyses of lateral condyle fracture fixation in paediatrics regarding configuration of Kirschner-wire.. BMC musculoskeletal disorders. 2022. DOI: 10.1186/s12891-022-05897-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.