MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.biomaterials.2012.03.028

Медицинская библиотека · Biomaterials · 2012

Biomimetic hydration lubrication with various polyelectrolyte layers on cross-linked polyethylene orthopedic bearing materials.

Kyomoto Masayuki, Moro Toru, Saiga Kenichi, Hashimoto Masami, Ito Hideya, Kawaguchi Hiroshi, Takatori Yoshio, Ishihara Kazuhiko

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Natural joints rely on fluid thin-film lubrication by the hydrated polyelectrolyte layer of cartilage. However, current artificial joints with polyethylene (PE) surfaces have considerably less efficient lubrication and thus much greater wear, leading to osteolysis and aseptic loosening. This is considered a common factor limiting prosthetic longevity in total hip arthroplasty (THA). However, such wear could be mitigated by surface modification to mimic the role of cartilage. Here we report the development of nanometer-scale hydrophilic layers with varying charge (nonionic, cationic, anionic, or zwitterionic) on cross-linked PE (CLPE) surfaces, which could fully mimic the hydrophilicity and lubricity of the natural joint surface. We present evidence to support two lubrication mechanisms: the primary mechanism is due to the high level of hydration in the grafted layer, where water molecules act as very efficient lubricants; and the secondary mechanism is repulsion of protein molecules and positively charged inorganic ions by the grafted polyelectrolyte layer. Thus, such nanometer-scaled hydrophilic polymers or polyelectrolyte layers on the CLPE surface of acetabular cup bearings could confer high durability to THA prosthetics.

Для цитирования: Kyomoto Masayuki, Moro Toru, Saiga Kenichi, Hashimoto Masami, Ito Hideya, Kawaguchi Hiroshi, Takatori Yoshio, Ishihara Kazuhiko. Biomimetic hydration lubrication with various polyelectrolyte layers on cross-linked polyethylene orthopedic bearing materials.. Biomaterials. 2012. DOI: 10.1016/j.biomaterials.2012.03.028.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.