MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/s24165189

Медицинская библиотека · Sensors (Basel, Switzerland) · 2024

Using Flexible-Printed Piezoelectric Sensor Arrays to Measure Plantar Pressure during Walking for Sarcopenia Screening.

Han Shulang, Xiao Qing, Liang Ying, Chen Yu, Yan Fei, Chen Hui, Yue Jirong, Tian Xiaobao, Xiong Yan

СтатьяПеревод в очереди

Аннотация

Sarcopenia is an age-related syndrome characterized by the loss of skeletal muscle mass and function. Community screening, commonly used in early diagnosis, usually lacks features such as real-time monitoring, low cost, and convenience. This study introduces a promising approach to sarcopenia screening by dynamic plantar pressure monitoring. We propose a wearable flexible-printed piezoelectric sensing array incorporating barium titanate thin films. Utilizing a flexible printer, we fabricate the array with enhanced compressive strength and measurement range. Signal conversion circuits convert charge signals of the sensors into voltage signals, which are transmitted to a mobile phone via Bluetooth after processing. Through cyclic loading, we obtain the average voltage sensitivity (4.844 mV/kPa) of the sensing array. During a 6 m walk, the dynamic plantar pressure features of 51 recruited participants are extracted, including peak pressures for both sarcopenic and control participants before and after weight calibration. Statistical analysis discerns feature significance between groups, and five machine learning models are employed to screen for sarcopenia with the collected features. The results show that the features of dynamic plantar pressure have great potential in early screening of sarcopenia, and the Support Vector Machine model after feature selection achieves a high accuracy of 93.65%. By combining wearable sensors with machine learning techniques, this study aims to provide more convenient and effective sarcopenia screening methods for the elderly.

Для цитирования: Han Shulang, Xiao Qing, Liang Ying, Chen Yu, Yan Fei, Chen Hui, Yue Jirong, Tian Xiaobao, Xiong Yan. Using Flexible-Printed Piezoelectric Sensor Arrays to Measure Plantar Pressure during Walking for Sarcopenia Screening.. Sensors (Basel, Switzerland). 2024. DOI: 10.3390/s24165189.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.