MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2015.08.004

Медицинская библиотека · Journal of cataract and refractive surgery · 2015

Suture-guided capsular tension ring insertion to reduce risk for iatrogenic zonular damage.

Page Timothy P

СтатьяПеревод в очереди

Аннотация

UNLABELLED: The capsular tension ring (CTR) is a useful device for managing a zonular dialysis. However, insertion of the CTR has potential complications. The CTR can damage zonular fibers during deployment into the capsular bag. Also, the angle and point of initial contact of the CTR with the capsular bag relative to the orientation of the dialysis must be considered to avoid damage to the zonular fibers. Adequate fill of the capsular bag with an ophthalmic viscosurgical device is important to minimize the risk for capsule entanglement with the leading eyelet of the CTR. A simple technique is described to prevent these complications. The technique can be used with both standard and modified CTRs.

FINANCIAL DISCLOSURE: Dr. Page is a consultant to Bausch & Lomb, Inc. and Abbott Medical Optics, Inc. He has no financial or proprietary interest in any material or method mentioned.

Для цитирования: Page Timothy P. Suture-guided capsular tension ring insertion to reduce risk for iatrogenic zonular damage.. Journal of cataract and refractive surgery. 2015. DOI: 10.1016/j.jcrs.2015.08.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.