MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/tnsre.2024.3444890

Медицинская библиотека · IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2024

Digital Biomarker for Muscle Function Assessment Using Surface Electromyography With Electrical Stimulation and a Non-Invasive Wearable Device.

Song Kwangsub, Eun Shin Hyung, Park Wookhyun, Lee Daehyun, Jang Jaeyoung, Yang Shim Ga, Choi Sangui, Kim Miji, Lee Hooman, Won Won Chang

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Sarcopenia is a comprehensive degenerative disease with the progressive loss of skeletal muscle mass with age, accompanied by the loss of muscle strength and muscle dysfunction. Individuals with unmanaged sarcopenia may experience adverse outcomes. Periodically monitoring muscle function to detect muscle degeneration caused by sarcopenia and treating degenerated muscles is essential. We proposed a digital biomarker measurement technique using surface electromyography (sEMG) with electrical stimulation and wearable device to conveniently monitor muscle function at home. When motor neurons and muscle fibers are electrically stimulated, stimulated muscle contraction signals (SMCSs) can be obtained using an sEMG sensor. As motor neuron activation is important for muscle contraction and strength, their action potentials for electrical stimulation represent the muscle function. Thus, the SMCSs are closely related to muscle function, presumptively. Using the SMCSs data, a feature vector concatenating spectrogram-based features and deep learning features extracted from a convolutional neural network model using continuous wavelet transform images was used as the input to train a regression model for measuring the digital biomarker. To verify muscle function measurement technique, we recruited 98 healthy participants aged 20-60 years including 48 [49%] men who volunteered for this study. The Pearson correlation coefficient between the label and model estimates was 0.89, suggesting that the proposed model can robustly estimate the label using SMCSs, with mean error and standard deviation of -0.06 and 0.68, respectively. In conclusion, measuring muscle function using the proposed system that involves SMCSs is feasible.

Для цитирования: Song Kwangsub, Eun Shin Hyung, Park Wookhyun, Lee Daehyun, Jang Jaeyoung, Yang Shim Ga, Choi Sangui, Kim Miji, Lee Hooman, Won Won Chang. Digital Biomarker for Muscle Function Assessment Using Surface Electromyography With Electrical Stimulation and a Non-Invasive Wearable Device.. IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society. 2024. DOI: 10.1109/tnsre.2024.3444890.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.