DOI 10.1016/j.gaitpost.2026.110285
Force-plate-free estimation of ground reaction forces and lower-limb joint moments during gait using a single RGB-D camera and physics-based optimization.
Аннотация
BACKGROUND
Three-dimensional (3D) gait analysis provides clinically relevant kinematics and kinetics but is limited by the high cost and extensive infrastructure of marker-based motion capture and force plates.
RESEARCH QUESTION: This study validates a hybrid markerless approach for gait analysis. The approach estimates 3D poses from a single RGB-D camera, recovers 3D ground reaction forces (GRFs) using physics-based optimization, and computes the lower limb joint moments using inverse dynamics without force plates.
METHODS
The study involved 10 healthy adults who walked at a self-selected speed. A marker-based motion capture system and embedded force plates were employed to collect data simultaneously. Two successful trials were conducted with each participant. Signals were synchronized, resampled to 120 Hz, and time-normalized to 0-100% stance (101 points). Waveform agreements for right-limb GRFs and sagittal plane hip, knee, and ankle angles and moments were quantified using the root mean square error (RMSE), normalized RMSE (NRMSE), bias, Pearson's correlation (r), and Lin's concordance correlation coefficient (CCC).
RESULTS
Sagittal joint angles showed high correlations (hip: r = 0.94 ± 0.05, RMSE = 11.84 ± 4.53°; knee: r = 0.91 ± 0.08, RMSE = 5.42 ± 1.93°; ankle: r = 0.89 ± 0.08, RMSE = 5.42 ± 2.10°). Sagittal joint moments were also correlated (hip: r = 0.89 ± 0.06, RMSE = 0.50 ± 0.16 N·m/kg; knee: r = 0.73 ± 0.15, RMSE = 0.40 ± 0.14 N·m/kg; ankle: r = 0.95 ± 0.02, RMSE = 0.40 ± 0.09 N·m/kg). The GRF agreement was component-dependent: anterior-posterior (CCC = 0.91 ± 0.04, NRMSE = 12.31 ± 3.26%), medial-lateral (CCC = 0.37 ± 0.18, NRMSE = 36.43 ± 18.57%), and vertical (CCC = 0.80 ± 0.10, NRMSE = 14.05 ± 3.23%).
SIGNIFICANCE: This single-camera pipeline showed feasibility for sagittal-plane gait analysis in healthy adults, but mediolateral GRF remains limited.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.