BACKGROUND

Whole body standing alignment (WBSA) in terms of biomechanics can be evaluated accurately only by referring the gravity line (GL) which lies on the gravity center (GC). Here, we introduce a method for estimating GL and simultaneous WBSA measurement using the EOS® imaging system and report on the reproducibility and reliability of the method.

METHODS

A 3-dimensional (3D) avatar to estimate GC was created following three steps: 3D reconstruction of the bone based on EOS images; deformation into a generic morphotype (MakeHuman statistical model) before density integration with 3D rasterization of the full body into 1-mm3 voxels (the content of each voxel is considered homogeneous); computation of the density of all the voxels provides the center of mass, which can be projected onto the floor as the GC of the full body, providing the GL in relation to the WBSA. The repeatability, reproducibility, and accuracy of the estimated GC and body weight of the avatar were compared with clinical estimation using a force plate in healthy volunteers and patients with degenerative and deformative diseases.

RESULTS

Statistical analyses of the data revealed that the repeatability and reproducibility of the estimation was high with intra-rater and inter-rater intraclass correlation coefficient. ≥0.999. The coordinate values of the GC and body weight estimation did not differ significantly between the avatar and force plate measurements, demonstrating the high accuracy of the method.

CONCLUSION

This new method of estimating GC and WBSA is reliable and accurate. Application of this method could allow clinicians to quickly and qualitatively evaluate WBSA with GL with various spinal malalignment pathologies.

Для цитирования: Hasegawa Kazuhiro, Amabile Celia, Nesme Matthieu, Dubousset Jean. Gravity center estimation for evaluation of standing whole body compensation using virtual barycentremetry based on biplanar slot-scanning stereoradiography - validation by simultaneous force plate measurement.. BMC musculoskeletal disorders. 2022. DOI: 10.1186/s12891-021-04948-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.