MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · JPMA. The Journal of the Pakistan Medical Association · 2021

Outcome of minimally invasive plate osteosynthesis using locking compression plate in long bone fractures.

Ali Muhammad, Khan Arif Mustafa, Azhar Muhammad Hamza, Javed Muhammad Tahir, Saleem Muhammad, Hafeez Zahid

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To evaluate radiological and clinical outcome of minimally invasive plate osteosynthesis (MIPO) using locking compression plate in long bone fractures.

METHODS

This was a prospective study for the long bones fracture managed by MIPO using locking compression plate in thirty patients from January to December 2017. All the skeletally mature patients and the patients with osteoporotic bones were included. Patients with open injuries, paediatric patients and plating done in non-traumatic conditions were excluded. Patients were followed as outpatient after one week, six weeks, after three months and then after 6 months.

RESULTS

Among 30 patients, 12(40%) were males and 18 (60%) females with male to female ratio 1:1.5. Average age of 30 patients was 59.5 ± 16.72 years (Range =21 to 91 years). Mean duration of surgery was 98.0±27.1 (Range=50 to 150) minutes. Majority 14(46.7%) had operative time 90-110 minutes. There were two complications, one (3.3%) had screw pull out and other had deep infection.

CONCLUSIONS

LCP system is a reliable and safe tool that extends the options for fixation by plating and has advantages over the other systems in term of stability that can be achieved with it especially in osteopenic bones.

Для цитирования: Ali Muhammad, Khan Arif Mustafa, Azhar Muhammad Hamza, Javed Muhammad Tahir, Saleem Muhammad, Hafeez Zahid. Outcome of minimally invasive plate osteosynthesis using locking compression plate in long bone fractures.. JPMA. The Journal of the Pakistan Medical Association. 2021.