MedElevator Войти в исследования
← Поиск публикаций

DOI 10.12200/j.issn.1003-0034.2021.09.004

Медицинская библиотека · Zhongguo gu shang = China journal of orthopaedics and traumatology · 2021

[Case control study on the application of artificial bone and autogenous bone in internal fixation of complex calcaneal fracture with special-shaped plate].

Zhou Liang, Chu Qi-Ping, Yu Hua-Jun

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To compare clinical effects of artificial bone and autogenous bone in internal fixation of complex calcaneal fracture with profitated plate.

METHODS

From April 2015 to April 2019, 60 patients with complex calcaneal fractures were treated with open reduction and heteromorphic plate internal fixation, and were divided into experiment group and control group by implant bone substitutes, and 30 patients in each group. In experiment group, there were 21 males and 9 females aged from 18 to 71 years old with an average of (36.85±7.42) years old;19 patients were classified to type Ⅲ and 11 patients were type Ⅳ according to Sanders classification;implanted with artificial bone. While in control group, there were 23 males and 7 females aged from 20 to69 years old with an average of (37.26±7.38) years old;18 patients were classified to type Ⅲ and 12 patients were type Ⅳ according to Sanders classification; implanted with autogenous bone. Operation time, intraoperative blood loss, drying time of incision, fracture healing time and complications were compared between two groups, changes of preoperative and postoperative Böhler angle and Gissane angle were also compared, and Maryland scoring was applied to evaluate recovery of affected foot.

RESULTS

Both of two groups were followed up from 3 to 15 months with an average of (10.15±2.67) months. Operation time and intraoperative blood loss in experiment group were (89.32±12.43) min, (101.64±5.13) ml, respectively;while in control group were (112.45±13.82) min, (119.01±5.26) ml, respectively;and there were statistical difference between two groups (P<0.05). There were no differences in drying time of incision, fracture healing time and complications between two groups(P>0.05). Preoperative and postoperative Böhler angle at 3 months in experiment group were (14.19± 2.47)°, (34.52±4.41)°;while in control group were (14.08±2.35)°, (33.67±4.36)°;preoperative and postoperative Gissane angel at 3 months in experiment group were (90.16±6.43)°, (131.45±9.83)°;while in control group were (90.11±6.37)°, (130.87±9.24)°;there were statistical significance in Böhler angle and Gissane angel compared with 3 months after operation and before operation between two groups (P<0.05);while no difference at 3 months after operation between two groups (P> 0.05). There were no statistical meaning in Maryland items, total score and good rate between two groups at the final following up (P>0.05).

CONCLUSION

Artificial bone and autogenous bone in internal fixation of complex calcaneal fracture with irregular plate have similar function in promoting fracture healing, drying time of incision, fracture healing time and complications, while artificial bone has better effects in reducing intraoperative blood loss, shorten operation time.

Для цитирования: Zhou Liang, Chu Qi-Ping, Yu Hua-Jun. [Case control study on the application of artificial bone and autogenous bone in internal fixation of complex calcaneal fracture with special-shaped plate].. Zhongguo gu shang = China journal of orthopaedics and traumatology. 2021. DOI: 10.12200/j.issn.1003-0034.2021.09.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.