MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00590-021-03115-9

Медицинская библиотека · European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2021

Plate fixation through the lateral extensile approach versus cannulated screw fixation through the sinus tarsi approach for calcaneal fracture: a multicenter, propensity score-matched TRON study.

Sugimoto Takuya, Tokutake Katsuhiro, Takegami Yasuhiko, Okui Nobuyuki, Kanayama Yasuhide, Inoue Hidenori, Sugimoto Ryosuke, Kagami Yujiro, Imagama Shiro

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

PURPOSE: For calcaneal fracture, plate fixation through lateral extensive approach (LEP) is the most common procedure performed to achieve anatomic reduction. However, wound complications sometimes occur after LEP. To reduce complications, minimally invasive operative methods with cannulated screw fixation through sinus tarsi approach (STS) were developed. The aim of this multicenter propensity-matched study was to compare the clinical and radiographic outcomes of LEP to those of STS for calcaneal fracture and to evaluate the incidence of postoperative complications including surgical site infection (SSI).

METHODS

We extracted 271 patients with calcaneal fracture undergoing surgery between January 2014 and March 2019 from our multicenter TRON database. We assessed the American Orthopedic Foot and Ankle Society (AOFAS) score at the final follow-up as the clinical outcome. We obtained the Bohler and Preis angles as radiographic parameters and also recorded the complications. We divided the subjects into two groups: LEP group and STS group. To adjust for baseline differences between the groups, a propensity score matching algorithm was used in a 1:1 ratio.

RESULTS

After matching, there were 32 fractures in each group. There was no significant difference between the LEP versus STS group in AOFAS score at final follow-up (90 vs 90 points, p = 0.98) and in the Bohler and Pries angles (19.2 vs. 18.0 degrees, p = 0.74 and 16.0 vs. 17.5 degrees, p = 0.47). The rate of SSI in the LEP group was higher than that in the STS group (21.9% vs. 0.0%, p = 0.01).

CONCLUSION

For calcaneal fracture, STS provides similar fixation effectiveness and functional outcomes as LEP while reducing the likelihood of infection.

Для цитирования: Sugimoto Takuya, Tokutake Katsuhiro, Takegami Yasuhiko, Okui Nobuyuki, Kanayama Yasuhide, Inoue Hidenori, Sugimoto Ryosuke, Kagami Yujiro, Imagama Shiro. Plate fixation through the lateral extensile approach versus cannulated screw fixation through the sinus tarsi approach for calcaneal fracture: a multicenter, propensity score-matched TRON study.. European journal of orthopaedic surgery & traumatology : orthopedie traumatologie. 2021. DOI: 10.1007/s00590-021-03115-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.