MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/prs.0000000000008333

Медицинская библиотека · Plastic and reconstructive surgery · 2021

Safety of Contemporary Resorbable Fixation Systems for Craniofacial Reconstruction in Pediatric Patients.

Kalmar Christopher L, Bushold Julia, Carlson Anna R, Zapatero Zachary D, Kosyk Mychajlo S, Swanson Jordan W, Taylor Jesse A, Bartlett Scott P

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Resorbable hardware allows adequate strength for maintaining the relative position of the craniofacial skeleton during osseous healing, and allowing subsequent growth in pediatric patients. The purpose of this study was to determine the complication profile of the latest copolymer of resorbable plates for craniofacial reconstruction in pediatric patients.

METHODS

Retrospective query of the operative billing record was performed for use of the DePuy Synthes Rapidsorb Fixation System at the authors' tertiary children's hospital from 2015 to 2019. Three hundred twenty-five patients were randomly selected for analysis of complications within the first postoperative year.

RESULTS

Median age at craniofacial reconstruction was 3.0 years, with 127 procedures (39.9 percent) performed for an intracranial mass and 141 procedures (44.3 percent) performed for craniosynostosis. Overall, 7.9 percent patients had a postoperative wound complication. The most common complications were dehiscence (3.8 percent), hematoma/seroma (3.5 percent), and infection (2.5 percent). There were no instances of extrusion, plate fracture, or screw loosening. Hardware complications in the temporoparietal region were more likely to occur at incision sites (p = 0.001), whereas wound complications at the frontal region were more likely to occur away from incision sites (p < 0.001). There were no differences in complications between plates secured with resorbable screws or with the resorbable injectable polymer system (p ≥ 0.161 for all). Radiotherapy was significantly implicated in development of clinical infection (p = 0.001), culture-positive infection (p < 0.001), readmission (p = 0.007), reoperation (p = 0.003), and plate removal (p = 0.007).

CONCLUSION

Resorbable cranial hardware has an overall favorable complication profile for craniofacial reconstruction in pediatric patients undergoing surgical intervention for craniosynostosis or intracranial mass resection.

Для цитирования: Kalmar Christopher L, Bushold Julia, Carlson Anna R, Zapatero Zachary D, Kosyk Mychajlo S, Swanson Jordan W, Taylor Jesse A, Bartlett Scott P. Safety of Contemporary Resorbable Fixation Systems for Craniofacial Reconstruction in Pediatric Patients.. Plastic and reconstructive surgery. 2021. DOI: 10.1097/prs.0000000000008333.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.