MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/bpo.0000000000000087

Медицинская библиотека · Journal of pediatric orthopedics · 2013

Confirmed specific ultrasonographic findings of pulled elbow.

Dohi Daisuke

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Pulled elbow is a disorder commonly observed in children in routine medical practice; however, when the circumstances involved in the injury are unknown, difficulty has been encountered in differential diagnosis whether it is a bone fracture or pulled elbow. One of the reasons involved has been the unavailability of diagnostic imaging in confirming the diagnosis of the pulled elbow. Therefore, the author had performed ultrasonography for the pulled elbow and studied the specific ultrasonographic findings of the same.

METHODS

Using as subjects a total of 70 cases of pulled elbow, with their age ranging from 4 months to 6 years, ultrasonography was performed from September 2010 to February 2013 with the use of Hitachi EUB 7500 ultrasonographic apparatus with a 12 MHz transducer. Careful observation was made of the specific ultrasonographic images of anterior long-axis view of the radiohumeral joint before and after the manipulation.

RESULTS

Before the manipulation in all the cases, both the supinator muscle originating from the annular ligament and the annular ligament itself were entrapped within the radiohumeral joint, and a hypoechoic image of J-shape (J-sign) was observed. After the manipulation, the hypoechoic image of the J-shape disappeared and normal annular ligament image was observed.

CONCLUSIONS

Accurate diagnosis of the pulled elbow can be done by ultrasonography through the confirmation of this specific J-sign.

LEVEL OF EVIDENCE: Level IV-diagnostic studies.

Для цитирования: Dohi Daisuke. Confirmed specific ultrasonographic findings of pulled elbow.. Journal of pediatric orthopedics. 2013. DOI: 10.1097/bpo.0000000000000087.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.