OBJECTIVES

In this study, we describe a novel hemiepiphysiodesis technique to prevent implant-related perichondrial ring injury in a rabbit model.

MATERIALS AND

METHODS

Proximal tibial epiphyseal plates of a total of 16 white New Zealand rabbits were used for this animal model. The subjects were divided into three equal groups as follows: Group 1 (Kirschner wire [K-wire]/cerclage), Group 2 (8-plate) right-hind legs, Group 3 (Control) left hind legs. Using anteroposterior radiography, the medial slope angle (MSA), articular line-diaphyseal angle (ALDA), and the angle between screws of 8-plate in lateral X-ray tibial slope angle (TSA) were measured. The radiographs were taken early postoperative (Day 1) and on sacrification day (Week 8). The histological evaluation of the perichondrial ring was made on a 7-mm axial section that stained with Safranin O/fast green at X10 magnification.

RESULTS

In both K-wire and 8-plate groups, the early postoperative ALDA and TSA were greater than the sacrification ALDA and TSA (p=0.028 and p<0.001, respectively). The early postoperative MSA was lower than the sacrification MSA in groups, (p<0.001). The MSA in the control group was lower than the K-wire and 8-plate groups (p<0.001 and p=0.009; respectively). The perichondrial ring thickness of the K-wire group was greater than the 8-plate group in histological evaluation (p<0.001).

CONCLUSION

Both of the K-wire and 8-plate groups showed similar angulation effects in the proximal tibia, although histologically less damage to the perichondrial ring was observed in the K-wire group, compared to the 8-plate group.

Для цитирования: Bayrak Alkan, Duramaz Altuğ, Kızılkaya Cemal, Çelik Malik, Kural Cemal, Altınay Serdar, Kural Alev, Başaran Serdar Hakan. Comparison of two types of fixation for proximal tibial epiphysiodesis: An experimental study in a rabbit model.. Joint diseases and related surgery. 2021. DOI: 10.52312/jdrs.2021.80219.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.