BACKGROUND

Recent studies report high hardware removal rates after plate fixation of midshaft clavicular fractures. Precontoured clavicle plates may decrease hardware-related complications while improving healing rates and patient-reported outcomes (PROs).

METHODS

Using a private-payer national database, we identified 7826 patients who underwent clavicle open reduction and internal fixation (ORIF) in 2007 to 2011. Database patients were tracked for 2 years to assess hardware removal and revision fixation. In addition, we retrospectively identified 73 patients who underwent plate fixation of midshaft clavicular fractures at our institution. These patients completed the Disabilities of Arm, Shoulder and Hand (DASH) assessment, the EQ-5D (EuroQol, Rotterdam, The Netherlands) quality of life assessment, and a hardware-related outcomes survey.

RESULTS

Among 7826 database patients, 994 (12.7%) underwent hardware removal and 78 (1%) required revision ORIF. The annual incidence of clavicle ORIF increased 61.5% between 2007 and 2011. In our institutional cohort, 56 patients (77%) were fixed with precontoured plates and 17 (23%) with standard plates. At a mean follow-up of 4.2 years, 11 patients (15%) underwent hardware removal and 1 patient (1.4%) experienced nonunion. Patients reported excellent outcomes, with average DASH of 4.0 ± 8.9 and EQ-5D of 0.89 ± 0.19. There were no differences in PROs, hardware removal, or union rate between plate types, although our study was underpowered for these outcomes. Patients who underwent hardware removal reported lower DASH, EQ-5D, satisfaction, and shoulder function compared with patients with hardware retained. Women were more likely to undergo hardware removal in the institutional (P = .009) and the database (P < .001) cohorts.

CONCLUSION

Displaced midshaft clavicle fractures have high union rates with precontoured plate fixation. Women are 4 times more likely than men to have hardware removed. Patients undergoing clavicle hardware removal report worse long-term outcomes than patients with hardware retained.

Для цитирования: Naimark Micah, Dufka Faustine L, Han Richard, Sing David C, Toogood Paul, Ma C Benjamin, Zhang Alan L, Feeley Brian T. Plate fixation of midshaft clavicular fractures: patient-reported outcomes and hardware-related complications.. Journal of shoulder and elbow surgery. 2015. DOI: 10.1016/j.jse.2015.09.029.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.