Validity of the modified versions of SARC-F+EBM for sarcopenia screening and diagnosis in China: the PPLSS study.
Аннотация
BACKGROUND AND
OBJECTIVES
It is recommended by Asian Working Group for Sarcopenia to early identify people at risk for sarcopenia using simple screening tools like SARC-F. The modified version SARC-F+EBM showed higher diagnostic performance. However, this cut-off value of body mass index (BMI) remained uncertain to be used in Chinese population. In this study, we used appropriate BMI recommended for Chinese older population and further modified SARC-F+EBM by combining calf circumference.
METHODS AND STUDY
DESIGN
Diagnostic tests were performed and the receiver operating characteristics analyses were conducted between the SARC-F, SARC-F+EBM (cut-off of BMI: ≤ 21 kg/m2), SARC-F+EBM (CN) (cut-off of BMI: ≤ 22 kg/m2), SARC-CalF and SARC-CalF+EBM (CN) (cut-off of BMI: ≤ 22 kg/m2) in 1660 community-dwelling participants aged ≥ 65 years from China.
RESULTS
The participants had an average age of 71.7±5.1 years, of which 56.8% were women. All the modified models could enhance the areas under the receiver operating characteristic curve (AUC) of original SARC-F (all p<0.001). The SARC-F+EBM (CN) also showed a significantly higher sensitivity of 47.4% (p<0.001) and an AUC of 0.809 (p=0.005) than SARC-F+EBM. SARC-CalF+EBM (CN) was validated to be of great diagnostic value of the highest AUC of 0.88 among these sarcopenia screening tools, including SARC-F, SARC-CalF and SARC-F+EBM (CN) (all p<0.001). Using this study population as a reference, the optimal cut-off value of SARC-CalF+EBM (CN) is ≥12 points, with a sensitivity of 79.3% and a specificity of 80.7%.
CONCLUSIONS
The SARC-F+EBM (CN) and SARC-CalF+EBM (CN) could enhance the diagnostic performance of SARC-F and SARC-F+EBM and are suitable sarcopenia screening tools for Chinese population.