m+Medelevator.RU
← Поиск публикаций
Clinical radiology · 2012

320-detector row CT angiography for detection and evaluation of intracranial aneurysms: comparison with conventional digital subtraction angiography.

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Wang H, Li W, He H, Luo L, Chen C, Guo Y

Аннотация

AIM: To compare the diagnostic performance of 320-detector row computed tomographic angiography (CTA) with digital subtraction angiography (DSA) for the detection and characterization of intracranial aneurysms.

MATERIALS AND METHODS: Fifty-two consecutive patients with non-traumatic subarachnoid haemorrhage (SAH) and suspected intracranial aneurysms were evaluated from January 2009 to October 2011. All underwent both 320-detector row volume CTA examination and DSA. CTA volume data were transmitted to a VITREA workstation and two physicians with experience in diagnostic imaging of the nervous system independently carried out image post-processing and assessed the results. The three-dimensional (3D) CTA and DSA images were assessed using intraoperative findings as the reference standard.

RESULTS: In 52 patients, 54 aneurysms were detected; 48 patients underwent surgery for 50 aneurysms. The overall sensitivity, specificity, and accuracy of 3D CTA were 96.3, 100, and 94.6%, respectively. Meanwhile, the overall sensitivity, specificity, and accuracy of DSA were 98.1, 98.1, and 95.1%, respectively. For aneurysms less than 3 mm, the sensitivity, specificity, and accuracy of 3D CTA were 81.8, 100, and 93.3%, respectively. The sensitivity, specificity, and accuracy of DSA for small aneurysms were 90.9, 100, and 96.2%, respectively. 3D CTA was superior to DSA in demonstrating aneurysmal calcification, parent artery, and surrounding vascular anatomy.

CONCLUSIONS: 3D CTA is a highly sensitive, specific, and non-invasive imaging method for diagnosis and evaluation of intracranial aneurysms. It also allows for precise depiction of aneurysm morphology. Therefore, 320-detector row CTA may be used as an alternative to DSA as a first-line imaging technique in patients with SAH.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты