Journal of orthopaedic surgery and research · 2024
Investigation of the pressure value while performing biceps tenodesis for superior capsuler reconstruction.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Bilgin Emre, Kilinc Bekir Eray, Arican Cigdem Dicle, Yilmaz Baris
Аннотация
BACKGROUND: To compare the histopathological results of biceps tenodesis (BT) performed with normal, low, and high pressures for superior capsule reconstruction (SCR) in rabbits with massive rotator cuff tears.
MATERIALS AND METHODS: Thirty rabbits were divided into three groups. Rabbits 1-10 underwent SCR with BT at the same pressure (Group 1), value measured in the groove; 50% lower (Group 2); 50% higher (Group 3). After the 4-week follow-up, shoulder were en-bloc excised and histopathological evaluation was performed with modified Bonar's scale. Results were compared between the groups, statistically.
RESULTS: Extracellular matrix were significantly lower in group 2 compared to the other groups (p < 0.05). Cellularity levels were significantly lower in group 2 compared to the other groups (p < 0.05). Group 2 had no difference between the sides (p > 0.05). Group 2 had lower vascularity levels compared to the other groups (p = 0.01).
DICSUSSION: When the biceps tendon was in the bicipital groove and in a more mobile state with lower pressure exposure. BT performed with a tension that creates less pressure than the biceps in the groove is more successful in SCR.
MATERIALS AND METHODS: Thirty rabbits were divided into three groups. Rabbits 1-10 underwent SCR with BT at the same pressure (Group 1), value measured in the groove; 50% lower (Group 2); 50% higher (Group 3). After the 4-week follow-up, shoulder were en-bloc excised and histopathological evaluation was performed with modified Bonar's scale. Results were compared between the groups, statistically.
RESULTS: Extracellular matrix were significantly lower in group 2 compared to the other groups (p < 0.05). Cellularity levels were significantly lower in group 2 compared to the other groups (p < 0.05). Group 2 had no difference between the sides (p > 0.05). Group 2 had lower vascularity levels compared to the other groups (p = 0.01).
DICSUSSION: When the biceps tendon was in the bicipital groove and in a more mobile state with lower pressure exposure. BT performed with a tension that creates less pressure than the biceps in the groove is more successful in SCR.