MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.injury.2016.07.056

Медицинская библиотека · Injury · 2016

Volar locking plate vs epibloc system for distal radius fractures in the elderly.

Solarino Giuseppe, Vicenti Giovanni, Abate Antonella, Carrozzo Massimiliano, Picca Girolamo, Colella Antonio, Moretti Biagio

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: To compare clinical outcomes of ORIF with volar locking plates and the Epibloc system (ES) in the treatment of distal radius fractures (DRFs) in patients aged over 65 years.

METHODS

We retrospectively examined a consecutive series of 100 patients with intra-articular or extra-articular DRF who were admitted to our Department of Orthopaedics and Traumatology between January 2007 and January 2013. Fifty patients were treated using the Epibloc System; and the other 50 patients using ORIF with volar locking plates. In all patients, functional evaluation (wrist range of motion [ROM], grip strength and Disability of the Arm, Shoulder and Hand [DASH] Score) and radiographic assessment (radial inclination, volar tilt, ulnar variance and articular congruity) were performed at 2 and 6 weeks, and 3, 6 and 12 months postoperatively; then every 12 months thereafter.

RESULTS

ORIF with volar locking plates was associated with better outcome than ES in the intra-articular and extra-articular DRF groups, generating higher average ROM, DASH and visual analogue scale (VAS) scores. Grip strength mean values, however, were quantified over the minimum level for a functional wrist (>60%) in both groups. There were no differences between the two techniques in X-ray parameters, and no further correlation was found with functional outcome and ROM.

CONCLUSIONS

In a low-functioning patient with multiple medical comorbidities, minimally-invasive surgery with the ES is a safe option, enables early mobilisation of the wrist and is likely to produce acceptable clinical outcomes.

Для цитирования: Solarino Giuseppe, Vicenti Giovanni, Abate Antonella, Carrozzo Massimiliano, Picca Girolamo, Colella Antonio, Moretti Biagio. Volar locking plate vs epibloc system for distal radius fractures in the elderly.. Injury. 2016. DOI: 10.1016/j.injury.2016.07.056.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…