MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jse.2016.01.014

Медицинская библиотека · Journal of shoulder and elbow surgery · 2016

Distal biceps reconstruction using an Achilles tendon allograft, transosseous EndoButton, and Pulvertaft weave with tendon wrap technique for retracted, irreparable distal biceps ruptures.

Phadnis Joideep, Flannery Olivia, Watts Adam C

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Distal biceps ruptures can result in ongoing pain and weakness when treated nonoperatively. If retraction of the tendon renders primary repair impossible, reconstruction using a graft is recommended. The current literature includes a variety of techniques with studies reporting small patient numbers. The aim of this study was to report the results of a larger cohort of patients using a technique modified from those previously described in the literature.

METHODS

Twenty-one consecutive male patients underwent distal biceps reconstruction through 2 small anterior incisions using an Achilles tendon allograft that was fixed distally using a transosseous EndoButton and secured proximally using a Pulvertaft weave and tendon wrap. The mean age was 44 years, and the mean time to surgery was 25 months (range, 2-96 months). Functional outcomes were collected prospectively.

RESULTS

The mean preoperative Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) score (11 patients) was 1.9 (range, 0-4.5). The mean postoperative Oxford Elbow Score, QuickDASH score, and Mayo Elbow Performance Score were 44.7 (range, 35-48), 4 (range, 0-20.5), and 92.9 (range, 70-100), respectively, at a mean follow up of 15 months (range, 6-35 months). The mean postoperative QuickDASH score was significantly improved compared with preoperatively (P < .001). All patients were satisfied and all returned to their previous level of activity. There were 2 transient lateral antebrachial cutaneous nerve paresthesias, and 2 patients had a 5° extension lag. There were no other complications.

CONCLUSION

Achilles allograft reconstruction of retracted irreparable distal biceps ruptures provides consistently good results with few complications using this technique.

Для цитирования: Phadnis Joideep, Flannery Olivia, Watts Adam C. Distal biceps reconstruction using an Achilles tendon allograft, transosseous EndoButton, and Pulvertaft weave with tendon wrap technique for retracted, irreparable distal biceps ruptures.. Journal of shoulder and elbow surgery. 2016. DOI: 10.1016/j.jse.2016.01.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.