MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/wno.0000000000001070

Медицинская библиотека · Journal of neuro-ophthalmology : the official journal of the North American Neuro-Ophthalmology Society · 2021

Interocular Difference in Retinal Nerve Fiber Layer Thickness Predicts Optic Neuritis in Pediatric-Onset Multiple Sclerosis.

Waldman Amy T, Benson Leslie, Sollee John R, Lavery Amy M, Liu Geraldine W, Green Ari J, Waubant Emmanuelle, Heidary Gena, Conger Darrel, Graves Jennifer, Greenberg Benjamin

СтатьяМногоцентровое исследованиеПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

BACKGROUND

Optical coherence tomography (OCT) is capable of quantifying retinal damage. Defining the extent of anterior visual pathway injury is important in multiple sclerosis (MS) as a way to document evidence of prior disease, including subclinical injury, and setting a baseline for patients early in the course of disease. Retinal nerve fiber layer (RNFL) thickness is typically classified as low if values fall outside of a predefined range for a healthy population. In adults, an interocular difference (IOD) in RNFL thickness greater than 5 μm identified a history of unilateral optic neuritis (ON). Through our PERCEPTION (PEdiatric Research Collaboration ExPloring Tests in Ocular Neuroimmunology) study, we explored whether RNFL IOD informs on remote ON in a multicenter pediatric-onset MS (POMS) cohort.

METHODS

POMS (defined using consensus criteria and first attack <18 years) patients were recruited from 4 academic centers. A clinical history of ON (>6 months prior to an OCT scan) was confirmed by medical record review. RNFL thickness was measured on Spectralis machines (Heidelberg, Germany). Using a cohort of healthy controls from our centers tested on the same machines, RNFL thickness <86 μm (<2 SDs below the mean) was defined as abnormal. Based on previously published findings in adults, an RNFL IOD >5 μm was defined as abnormal. The proportions of POMS participants with RNFL thinning (<86 μm) and abnormal IOD (>5 μm) were calculated. Logistic regression was used to determine whether IOD was associated with remote ON.

RESULTS

A total of 157 participants with POMS (mean age 15.2 years, SD 3.2; 67 [43%] with remote ON) were enrolled. RNFL thinning occurred in 45 of 90 (50%) ON eyes and 24 of 224 (11%) non-ON eyes. An IOD >5 μm was associated with a history of remote ON (P < 0.001). An IOD >5 μm occurred in 62 participants, 40 (65%) with remote ON. Among 33 participants with remote ON but normal RNFL values (≥86 μm in both eyes), 14 (42%) were confirmed to have ON by IOD criteria (>5 μm).

CONCLUSIONS

In POMS, the diagnostic yield of OCT in confirming remote ON is enhanced by considering RNFL IOD, especially for those patients with RNFL thickness for each eye in the normal range. An IOD >5 μm in patients with previous visual symptoms suggests a history of remote ON.

Для цитирования: Waldman Amy T, Benson Leslie, Sollee John R, Lavery Amy M, Liu Geraldine W, Green Ari J, Waubant Emmanuelle, Heidary Gena, Conger Darrel, Graves Jennifer, Greenberg Benjamin. Interocular Difference in Retinal Nerve Fiber Layer Thickness Predicts Optic Neuritis in Pediatric-Onset Multiple Sclerosis.. Journal of neuro-ophthalmology : the official journal of the North American Neuro-Ophthalmology Society. 2021. DOI: 10.1097/wno.0000000000001070.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.