Effectiveness of intraoperative nerve monitoring in reducing rates of recurrent laryngeal nerve injury in aerodigestive and cardiovascular pediatric surgery.

Izadi Shawn, Chiu Megan Z, Koo Donna C, Meisner Jay, Mohammed Somala, Demehri Farokh R, Smithers Jason, Munoz Carlos, Choi Sukgi, Zendejas Benjamin

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To investigate the effectiveness of intraoperative nerve monitoring at decreasing vocal fold movement impairment in children undergoing at-risk procedures.

BACKGROUND

Children undergoing aerodigestive or cardiovascular procedures are at risk for recurrent laryngeal nerve injury, leading to vocal fold movement impairment. Although intraoperative nerve monitoring has been shown to decrease recurrent laryngeal nerve injury in adults, there is paucity of data in children.

METHODS

This was a retrospective, single-center cohort study of children who underwent airway, esophageal, or great vessel surgery between 2018 and 2023. Vocal fold movement impairment was evaluated with pre- and postoperative awake flexible fiberoptic laryngoscopy. Vocal fold movement impairment rates and associated characteristics were compared between those with and without intraoperative nerve monitoring.

RESULTS

Among 387 children undergoing 426 at-risk procedures, intraoperative nerve monitoring was used in 72.1% (n = 307) of procedures. Intraoperative nerve monitoring significantly reduced postoperative vocal fold movement impairment compared with those without (11.4% vs 20.2%, P = .019, 43.6% relative risk reduction, number needed to treat: 12). In children with a pre-existing vocal fold movement impairment (n = 79, 18.5%), intraoperative nerve monitoring provided enhanced protection (vocal fold movement impairment 7.8% with intraoperative nerve monitoring compared with 25% without, P = .046, 68.6% relative risk reduction, number needed to treat: 3). Bilateral vocal fold movement impairment was 14 times more likely without intraoperative nerve monitoring (1.8% overall, 0.3% with intraoperative nerve monitoring, 5.6% without; 95% confidence interval 1.6-123.2; P = .006). Increasing intraoperative nerve monitoring use correlated with decreasing vocal fold movement impairment rates year over year (P = .046). Multivariable logistic regression demonstrated intraoperative nerve monitoring to remain significantly associated with reduced risk of vocal fold movement impairment (odds ratio, 0.48; 95% confidence interval, 0.26-0.85; P = .013).

CONCLUSION

Intraoperative nerve monitoring in children seems effective at decreasing recurrent laryngeal nerve injury and consequently vocal fold movement impairment. Intraoperative nerve monitoring should be considered in children undergoing cervicothoracic or cardiothoracic procedures, especially in those with preoperative vocal fold movement impairment.

Для цитирования: Izadi Shawn, Chiu Megan Z, Koo Donna C, Meisner Jay, Mohammed Somala, Demehri Farokh R, Smithers Jason, Munoz Carlos, Choi Sukgi, Zendejas Benjamin. Effectiveness of intraoperative nerve monitoring in reducing rates of recurrent laryngeal nerve injury in aerodigestive and cardiovascular pediatric surgery.. Surgery. 2024. DOI: 10.1016/j.surg.2024.08.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.