MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2214/ajr.11.6545

Медицинская библиотека · AJR. American journal of roentgenology · 2011

Unusual complication after left-lobe liver biopsy for diffuse liver disease: severe bleeding from the superior epigastric artery.

Vijayaraghavan Gopal, Sheehan David, Zheng Larry, Hussain Sarwat, Ferrucci Joseph

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Imaging-guided parenchymal liver biopsy for diffuse liver disease is increasingly performed via an epigastric route from the left lobe, as opposed to the more traditional intercostal right-sided approach.

MATERIALS AND

METHODS

We conducted a retrospective analysis of all liver biopsies performed at our department for 3 years (July 2007 through June 2010). A total of 1028 liver biopsies were performed during this period. Of these, 776 biopsies were performed for diffuse medical liver disease. Electronic medical records were reviewed for any documented complications.

RESULTS

We identified six cases (0.8%) of documented significant bleeding after 776 biopsies. All bleeding complications were associated with the left-sided epigastric approach. No documented case of major bleeding from the right-sided approach was recorded during the same period. We describe four patients with severe bleeding complications in which classic imaging features were noted on CT, pointing to injury of the superior epigastric artery as the possible cause of the bleeding.

CONCLUSION

It is important to recognize the subtle CT signs of superior epigastric artery bleeding because the traditional femoral approach with angiography of the hepatic and portal vessels may not reveal active bleeding. The superior epigastric artery, rather than the hepatic arteries, should be evaluated. A brachial approach for the angiogram may be the more optimal technique.

Для цитирования: Vijayaraghavan Gopal, Sheehan David, Zheng Larry, Hussain Sarwat, Ferrucci Joseph. Unusual complication after left-lobe liver biopsy for diffuse liver disease: severe bleeding from the superior epigastric artery.. AJR. American journal of roentgenology. 2011. DOI: 10.2214/ajr.11.6545.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление