MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1259/bjr.20190170

Медицинская библиотека · The British journal of radiology · 2019

Physiological motion of the optic chiasm and its impact on stereotactic radiosurgery dose.

Xiang Michael, Chan Cynthia, Wang Lei, Jani Khushboo, Holdsworth Samantha J, Iv Michael, Pollom Erqi L, Soltys Scott G

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Avoidance of radiation-induced optic neuropathy (RION) from stereotactic radiosurgery (SRS) requires precise anatomical localization; however, no prior studies have characterized the physiologic motion of the optic chiasm. We measured the extent of chiasm motion and its impact on SRS dose.

METHODS

In this cross-sectional study, serial MRI was performed in multiple planes in 11 human subjects without optic pathway abnormalities to determine chiasm motion across time. Subsequently, the measured displacement was applied to the hypothetical chiasm dose received in 11 patients treated with SRS to a perichiasmatic lesion.

RESULTS

On sagittal images, the average anteroposterior chiasm displacement was 0.51 mm [95% confidence interval (CI) 0.27 - 0.75 mm], and the average superior-inferior displacement was 0.48 mm (95% CI 0.22 - 0.74 mm). On coronal images, the average superior-inferior displacement was 0.42 mm (95% CI 0.13 - 0.71 mm), and the average lateral displacement was 0.75 mm (95% CI 0.42 - 1.08 mm). In 11 patients who underwent SRS to a perichiasmatic lesion, the average displacements increased the maximum chiasm dose (Dmax) by a mean of 14 % (range 6-23 %; p < 0.001).

CONCLUSION

Average motion of the optic chiasm was approximately 0.50-0.75 mm, which increased chiasm Dmax by a mean of 14%. In the occasional patient with higher-than-average chiasm motion in a region of steep dose gradient, the increase in chiasm Dmax and risk of RION could be even larger. Similarly, previously reported chiasm dose constraints may underestimate the true dose received during radiosurgery.

ADVANCES IN KNOWLEDGE: To limit the risk of RION, clinicians may consider adding a 0.50-0.75 mm expansion to the chiasm avoidance structure.

Для цитирования: Xiang Michael, Chan Cynthia, Wang Lei, Jani Khushboo, Holdsworth Samantha J, Iv Michael, Pollom Erqi L, Soltys Scott G. Physiological motion of the optic chiasm and its impact on stereotactic radiosurgery dose.. The British journal of radiology. 2019. DOI: 10.1259/bjr.20190170.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.