Percutaneous plating in paediatric tibial fractures.

Yusof Nazri Mohd, Oh Chang-Wug, Oh Jong-Keon, Kim Joon-Woo, Min Woo-Kie, Park Il-Hyung, Kim Hee-June

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Although non-operative treatment is a mainstay of tibial fracture management in children, certain fractures require a surgical approach. However, choices concerning optimal methods and implants are difficult. The purpose of this study was to determine the effectiveness of percutaneous plating of tibial fractures in children.

MATERIALS AND

METHODS

Sixteen tibial fractures treated using the percutaneous plating technique between 2000 and 2007 were reviewed. The mean age at operation was 10 years 9 months (range: 6-16 years). There were eight open and closed fractures each. Operative indications were acute fractures with associated injuries or fractures, open fractures and compartment syndrome. Nonunions or failures following other treatments were also indicated. Without exposing the fracture sites, the plates were fixed through a subcutaneous tunnel from remote incisions.

RESULTS

All fractures healed without a bone graft. The mean time required for union was 13 weeks (range: 8-24 weeks). No major complications such as malunion, implant failure or deep infection occurred. With the exception of one case with a 15-mm overgrowth, no discrepancy in leg length over 10mm was encountered. Other minor complications included one case each of transient superficial infection and skin irritation caused by the plate. All patients achieved an excellent or satisfactory clinical outcome with no limping.

SUMMARY: Percutaneous plating technique is a safe alternative treatment for paediatric tibial fractures that are difficult to manage using other methods.

Для цитирования: Yusof Nazri Mohd, Oh Chang-Wug, Oh Jong-Keon, Kim Joon-Woo, Min Woo-Kie, Park Il-Hyung, Kim Hee-June. Percutaneous plating in paediatric tibial fractures.. Injury. 2009. DOI: 10.1016/j.injury.2009.02.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.