m+Medelevator.RU
← Поиск публикаций
International orthopaedics · 2024

Optimising safe margins in shoulder surgeries: a cadaveric study on brachial plexus nerves with anthropometric and movement correlation.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kodandapani K, Sangani Karthik, Chakrapani Arjun, Vedapriya Aparna K

Аннотация

PURPOSE: Shoulder surgeries, vital for diverse pathologies, pose a risk of iatrogenic nerve damage. Existing literature lacks diverse bone landmark-specific nerve position data. The purpose of this study is to address this gap by investigating such relationships.

METHOD: This cadaveric study examines axillary, radial and suprascapular nerves' relation with acromion, coracoid and greater tuberosity of the humerus (GT). It also correlates this data with humeral lengths and explores nerve dynamics in relation to arm positions.

RESULTS: The mean distance from the axillary nerve to (i) GT was 4.38 cm (range 3.32-5.44, SD 0.53), (ii) acromion was 6.42 cm (range 5.03-7.8, SD 0.694) and (iii) coracoid process was 4.3 cm (range 2.76-5.84, SD 0.769). Abduction brought the nerve closer by 0.36 cm, 0.35 cm and 0.53 cm, respectively. The mean distance from radial nerve to (i) GT was 5.46 cm (range 3.78-7.14, SD 0.839), (ii) acromion was 7.82 cm (range 5.4-10.24, SD 1.21) and (iii) tip of the coracoid process was 6.09 cm (range 4.07-8.11 cm, SD 1.01). The mean distance from the suprascapular nerve to the acromion was 4.2 cm (range 3.1-5.4, SD 0.575). The mean humeral length was noted to be 27.83 cm (range 25.3-30.7, SD 1.13). There was no significant correlation between these distances and humeral lengths.

CONCLUSION: It is essential to exercise caution to avoid axillary nerve damage during the abduction manoeuvre, as its distance from the greater tuberosity and tip of the coracoid process has shown a significant reduction. The safe margins, in relation to the length of the humerus and consequently the patient's stature, exhibit no significant variation. In situations where the greater tuberosity (GT) and the border of the acromion are inaccessible due to reasons such as trauma, the tip of the coracoid process can serve as a dependable bone landmark for establishing a secure surgical margin.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты