MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12871-020-01127-2

Медицинская библиотека · BMC anesthesiology · 2020

Flexible fibreoptic intubation in swine - improvement for resident training and animal safety alike.

Ruemmler Robert, Ziebart Alexander, Ott Thomas, Dirvonskis Dagmar, Hartmann Erik Kristoffer

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Efficient airway management to facilitate tracheal intubation encompasses essential skills in anaesthesiologic and intensive care. The application of flexible fibreoptic intubation in patients with difficult airways has been identified as the recommended method in various international guidelines. However, providing the opportunity to adequately train residents can be challenging. Using large animals for practice during ongoing studies could help to improve this situation, but there is no recent data on fibreoptic intubation in swine available.

METHODS

Thirty male German landrace pigs were anesthetized, instrumented and randomized into two groups. The animals were either intubated conventionally using direct laryngoscopy or a single-use flexible video-endoscope. The intervention was carried out by providers with 3 months experience in conventional intubation of pigs and a brief introduction into endoscopy. Intubation attempts were supervised and aborted, when SpO2 dropped below 93%. After three failed attempts, an experienced supervisor intervened and performed the intubation. Intubation times and attempts were recorded and analysed.

RESULTS

Flexible fibreoptic intubation showed a significantly higher success rate in first attempt endotracheal tube placement (75% vs. 47%) with less attempts overall (1.3 ± 0.6 vs. 2.1 ± 1.3, P = 0.043). Conventional intubation was faster (42 s ± 6 s vs. 67 s ± 10s, P < 0.001), but showed a higher complication rate and more desaturation episodes during the trial.

CONCLUSIONS

Flexible fibreoptic intubation in swine is feasible and appears to be a safer and more accessible method for inexperienced users to learn. This could not only improve resident training options in hospitals with animal research facilities but might also prevent airway complications and needless animal suffering.

Для цитирования: Ruemmler Robert, Ziebart Alexander, Ott Thomas, Dirvonskis Dagmar, Hartmann Erik Kristoffer. Flexible fibreoptic intubation in swine - improvement for resident training and animal safety alike.. BMC anesthesiology. 2020. DOI: 10.1186/s12871-020-01127-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.